DS26502LN Maxim Integrated Products, DS26502LN Datasheet - Page 100

no-image

DS26502LN

Manufacturer Part Number
DS26502LN
Description
Timers & Support Products E1-T1-J1-64KCC BITS Element 64kHz - G.70
Manufacturer
Maxim Integrated Products
Type
Clock Recoveryr
Datasheet

Specifications of DS26502LN

Supply Voltage (max)
3.46 V
Supply Voltage (min)
3.13 V
Maximum Operating Temperature
+ 85 C
Minimum Operating Temperature
- 40 C
Mounting Style
SMD/SMT
Supply Current
85 mA
Package / Case
LQFP-64

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
DS26502LN+
Manufacturer:
Maxim Integrated Products
Quantity:
135
Part Number:
DS26502LN+
Manufacturer:
Maxim Integrated
Quantity:
10 000
Part Number:
DS26502LN+
Manufacturer:
DALLAS
Quantity:
20 000
DS26502 T1/E1/J1/64KCC BITS Element
TAP Controller State Machine
The TAP controller is a finite state machine that responds to the logic level at JTMS on the rising edge of
JTCLK. See
Figure
17-2.
Test-Logic-Reset
Upon power-up, the TAP controller will be in the test-logic-reset state. The instruction register will
contain the IDCODE instruction. All system logic of the device will operate normally.
Run-Test-Idle
The run-test-idle is used between scan operations or during specific tests. The instruction register and test
registers will remain idle.
Select-DR-Scan
All test registers retain their previous state. With JTMS LOW, a rising edge of JTCLK moves the
controller into the capture-DR state and will initiate a scan sequence. JTMS HIGH during a rising edge
on JTCLK moves the controller to the select-IR-scan state.
Capture-DR
Data can be parallel-loaded into the test-data registers selected by the current instruction. If the
instruction does not call for a parallel load or the selected register does not allow parallel loads, the test
register will remain at its current value. On the rising edge of JTCLK, the controller will go to the shift-
DR state if JTMS is LOW or it will go to the exit1-DR state if JTMS is HIGH.
Shift-DR
The test-data register selected by the current instruction will be connected between JTDI and JTDO and
will shift data one stage toward its serial output on each rising edge of JTCLK. If a test register selected
by the current instruction is not placed in the serial path, it will maintain its previous state.
Exit1-DR
While in this state, a rising edge on JTCLK will put the controller in the update-DR state, which
terminates the scanning process, if JTMS is HIGH. A rising edge on JTCLK with JTMS LOW will put
the controller in the pause-DR state.
Pause-DR
Shifting of the test registers is halted while in this state. All test registers selected by the current
instruction will retain their previous state. The controller will remain in this state while JTMS is LOW. A
rising edge on JTCLK with JTMS HIGH will put the controller in the exit2-DR state.
Exit2-DR
A rising edge on JTCLK with JTMS HIGH while in this state will put the controller in the update-DR
state and terminate the scanning process. A rising edge on JTCLK with JTMS LOW will enter the shift-
DR state.
Update-DR
A falling edge on JTCLK while in the update-DR state will latch the data from the shift register path of
the test registers into the data output latches. This prevents changes at the parallel output due to changes
in the shift register.
100 of 125