The following steps should be followed:
Every time the channel frequency is programmed or the
PLL+VCO is enabled, the FSM needs to be reset to be
used again for the next time. This reset operation does
not affect the PLL or VCO. To reset the FSM, set D7 = 0
(A3:A0 = 0101).
Every channel frequency maps to some VCO sub-
band. Each VCO sub-band has a digital code, of which
the 2 LSBs (B1:B0) are readable. The B1:B0 code can
be read through pin LD by programming D3:D0 = 0111
(A3:A1 = 0000) for B1, or D3:D0 = 0110 (A3:A1 = 0000)
for B0 (see Table 6).
For faster settling, the VCO sub-band (B1:B0) can be
directly programmed through the SPI. First, the B1:B0
code for every channel frequency must be determined.
Once this is known, the B1:B0 code is directly pro-
grammed along with the PLL divider values, for the
given channel frequency. The PLL settling time in this
case is approximately 50µs.
Large temperature changes (>+50°C) may cause the
channel frequency to move into an adjacent sub-band.
To determine the correct sub-band, two on-chip com-
parators monitor the VCO control voltage (V
These comparator logic outputs can be read through
Single-/Dual-Band 802.11a/b/g
World-Band Transceiver ICs
Table 6. B1:B0 VCO Sub-Band
Assignments (Read Back Through Lock-
Detect Pin)
30
1) Set D8 = 0 (A3:A0 = 0101) to enable the automatic
2) Enable the PLL and VCO if required. If required,
3) Set D7 = 1 (A3:A0 = 0101) to start the FSM. The FSM
4) The VCO sub-band selection and PLL settling time
VCO sub-band selection by the FSM.
program the divider ratios corresponding to the
desired channel frequency.
should only be started after PLL and VCO are
enabled, or after channel frequency is changed.
takes less than approximately 300µs. After the
band switching is completed and the PLL has
locked to the correct channel frequency, the FSM
stops automatically.
B1
______________________________________________________________________________________
0
0
1
1
B0
0
1
0
1
Manual VCO Sub-Band Selection
Band 0 (lowest frequency band)
Band 1
Band 2
Band 3 (highest frequency band)
VCO FREQUENCY BAND
TUNE
).
the LD pin to decide whether the frequency sub-band
is correct or needs to be reprogrammed.
The following steps need to be followed to complete
manual PLL frequency acquisition and VCO sub-band
selection:
If the PLL and VCO are continuously active (i.e., no
reprogramming) and the die temperature changes by
50°C (as indicated by the on-chip temperature sensor),
there is a possibility that the PLL may get unlocked due
Table 7. D10:D9 VCO Sub-Band
Assignments (For Programming Through
SPI)
Table 8. Comparator-Output Definition
A3:A1 = 0000;
D3:D0 = 0101
1) Set D8 = 1 (A3:A0 = 0101) to enable manual VCO
2) Enable the PLL and VCO if required. If required,
3) Set D10:D9 (A3:A0 = 0101) to program the VCO
4) After 50µs of PLL settling time, the comparator out-
5) Based on the comparator outputs, the VCO frequen-
D10
sub-band selection.
program the divider ratios corresponding to the
desired channel frequency.
frequency sub-band according to Table 7. D10:D9
correspond to the same assignments as B1:B0.
After D10:D9 are programmed, 50µs is required to
allow the PLL to settle.
puts can be read through pin LD (see Table 8).
cy sub-band is programmed again according to
Table 8 until the frequency acquisition is achieved.
0
0
1
1
0
0
1
1
D9
0
1
0
1
A3:A1 = 0000;
D3:D0 = 0100
0
1
0
1
Band 0
Band 1
Band 2
Band 3
Large Temperature Changes
PROGRAMMED VCO
FREQUENCY BAND
Program to a lower sub-band
if VCO is not in Band 0.
No change.
Program to a higher sub-
band if VCO is not in Band 3.
Invalid state, does not occur.
RESPONSE