Linear & Switching Power Supplies 100W 5V 12A 12V 5A/ -12V 1A

MAP110-4000

Manufacturer Part NumberMAP110-4000
DescriptionLinear & Switching Power Supplies 100W 5V 12A 12V 5A/ -12V 1A
ManufacturerPOWER ONE
TypeOpen Frame
MAP110-4000 datasheet
 

Specifications of MAP110-4000

Input Voltage85 to 264VNumber Of Outputs4
Mounting StyleScrewOutput Current (max)12/5/1/1A
Output Voltage5/12/-12/-5VOutput Power (max)80W
Input Frequency47 to 63HzEfficiency80%
Screening LevelCommercialProduct Length (mm)177.8mm
Product Height (mm)50mmProduct Depth (mm)109.2mm
Operating Temperature Min Deg. C0COperating Temperature Max Deg. C70C
Pin Count19ProductSwitching
Commercial/medicalCommercialOutput Power Rating100 W
Output Voltage (channel 1)5 VOutput Current (channel 1)12 A, 20 A
Output Voltage (channel 2)12 VOutput Current (channel 2)5 A, 9 A
Output Voltage (channel 3)- 12 VOutput Current (channel 3)1 A, 1.5 A
Dimensions7 in L x 4.3 in W x 1.97 in HBrand/seriesMAP110 Series
ConfigurationOpen-FrameCurrent, Input3.5 A (RMS) @ 85 VAC]
Current, Leakage750 μA (Max.)Hold Time40 ms (Min.)
Mounting TypePanelOperationSwitching
Output-12 VDC @ 1/1.5 A, -5 VDC @ 1/1.5 A, +5 VDC @ 12/20 A, +12 VDC @ 5/9 APower, Output80 W
Power, Rating80 WPrimary TypeAC-DC
Special FeaturesRemote SenseTemperature, Operating0 to +50 °C
Voltage, Input85 to 264 VACVoltage, Output-12, -5, +5, +12 VDC
Voltage, Output 15 VVoltage, Output 2+12 V
Voltage, Output 3-12 VVoltage, Output 4-5 V
En61000-4-2 Esd Level 4 (8 Kv)All Map Products En61000-4-3 Radiated Level 3 (10 V/m)All Map Products
Universal Input90-132 VAC or 175-264 VACLead Free Status / RoHS StatusNot Compliant
1
Page 1
2
Page 2
3
Page 3
4
Page 4
5
Page 5
Page 1/5

Download datasheet (125Kb)Embed
Next
Description
Power-One’s MAP110 Series of power supplies combines low cost and universal input in a board-only power solution to meet
commercial and industrial requirements. Full international safety, EMI, and ESD compliance ensure worldwide acceptance. All units
bear the CE Mark.
Wide dynamic output current and fixed-frequency operation simplifies system level operation. The MAP110 series is configured to an
international standard footprint. Input and output connections are made via popular single-row Molex connectors.
Single output models feature wide-range output adjustability to meet a wide variety of standard and user-specific output voltage
requirements.
Single-Output Model Selection
OUTPUT
ADJUSTMENT
MODEL
VOLTAGE
RANGE
MAP110-1005
5V
4.95V to 5.50V
MAP110-1012 12V/15V
11.25V to 15.75V
MAP110-1024 24V/28V
22.8V to 29.2V
NOTES: 1) Maximum peak-to-peak noise expressed as a percentage of output voltage, 20 MHz bandwidth.
2) MAP110-1012 output currents are expressed as 12V/15V operation. MAP110-1024 output currents are expressed as 24V/28V operation.
Multiple-Output Model Selection
– 80W Convection Cooled, 110W Forced-Air Cooled (200 LFM)
OUTPUT
ADJUSTMENT
MODEL
VOLTAGE
RANGE
+5V
4.75V to 5.25V
+12V
Fixed
MAP110-4000
-12V
Fixed
-5V
Fixed
+5V
4.75V to 5.25V
+24V
Fixed
MAP110-4001
-12V
Fixed
+12V
Fixed
+5V
4.75V to 5.25V
+12V
Fixed
MAP110-4002
-12V
Fixed
+12V
Fixed
+5V
4.75V to 5.25V
+15V
Fixed
MAP110-4003
-15V
Fixed
-5V
Fixed
+5V
4.75V to 5.25V
+24V
Fixed
MAP110-4004
-15V
Fixed
+15V
Fixed
Model numbers highlighted in yellow or shaded are not recommended for new designs.
MCD10142 Rev. 1.0, 27-Jan-10
MAP110 AC-DC Series Data Sheet
Features
• RoHS lead-solder-exemption compliant
• New 3.3 V and 5 V output models
• Universal input 85-264 VAC
• Industry-standard footprint: 7.00" x 4.30" x 1.97"
(177.8 x 109.2 x 50.0 mm)
• Input transient & ESD compliance to EN61000-4-2/-3/-4
• Greater than 134,000 hours MTBF
• Remote sense and overvoltage protection on single
output units and main output of multiple output units
• Options include overtemperature protection,
Power Fail signal, chassis, & cover
CONVECTION COOLED
FORCED AIR
OUTPUT CURRENT
OUTPUT CURRENT
REGULATION
16A
22A
7.5/6A (Note 2)
10/8A (Note 2)
3.8/3.2A (Note 2)
5.0/4.3A (Note 2)
CONVECTION COOLED
FORCED AIR
CURRENT (NOTE 1)
CURRENT
REGULATION
12A/20A PK
12A/20A PK
5A/9A PK
5A/9A PK
1A/1.5A PK
1A/1.5A PK
1A/1.5A PK
1A/1.5A PK
12A/20A PK
12A/20A PK
3A/4.5A PK
3A/4.5A PK
1A/1.5A PK
1A/1.5A PK
1A/1.5A PK
1A/1.5A PK
12A/20A PK
12A/20A PK
5A/9A PK
5A/9A PK
1A/1.5A PK
1A/1.5A PK
1A/1.5A PK
1A/1.5A PK
12A/20A PK
12A/20A PK
5A/7.3A PK
5A/7.3A PK
1A/1.5A PK
1A/1.5A PK
1A/1.5A PK
1A/1.5A PK
12A/20A PK
12A/20A PK
3A/4.5A PK
3A/4.5A PK
1A/1.5A PK
1A/1.5A PK
1A/1.5A PK
1A/1.5A PK
Page 1 of 5
LINE
LOAD
RIPPLE & NOISE
REGULATION
%p-p (NOTE 1)
0.2%
1%
1%
0.1%
0.5%
1%
11.97V to 12.02V
0.1%
0.5%
1%
23.95V to 24.05V
LINE
LOAD
RIPPLE & NOISE
REGULATION
%p-p (NOTE 2)
0.2%
0.5%
1%
5.09V to 5.11V
0.2%
1%
1%
11.97V to 12.03V
0.2%
1%
1%
-11.4V to -12.6V
0.2%
1.5%
1%
-4.75V to -5.25V
0.2%
0.5%
1%
5.09V to 5.11V
0.1%
1%
1%
23.94V to 24.06V
0.1%
1%
1%
-11.4V to -12.6V
0.1%
1%
1%
11.4V to 12.6V
0.2%
0.5%
1%
5.09V to 5.11V
0.1%
1%
1%
11.97V to 12.03V
0.1%
1%
1%
-11.4V to -12.6V
0.1%
1%
1%
11.4V to 12.6V
0.2%
0.5%
1%
5.09V to 5.11V
0.1%
1%
1%
14.96V to 15.04V
0.1%
1%
1%
-14.3V to -15.7V
0.2%
1.5%
1%
-4.75V to -5.25V
0.2%
0.5%
1%
5.09V to 5.11V
0.1%
1%
1%
23.94V to 24.06V
0.1%
1%
1%
-14.3V to -15.7V
0.1%
1%
1%
14.3V to 15.7V
www.power-one.com
INITIAL SETTING
ACCURACY
5.09V to 5.11V
INITIAL SETTING
ACCURACY

MAP110-4000 Summary of contents

  • Page 1

    ... MAP110-1012 output currents are expressed as 12V/15V operation. MAP110-1024 output currents are expressed as 24V/28V operation. Multiple-Output Model Selection – 80W Convection Cooled, 110W Forced-Air Cooled (200 LFM) OUTPUT ADJUSTMENT MODEL VOLTAGE RANGE +5V 4.75V to 5.25V +12V Fixed MAP110-4000 -12V Fixed -5V Fixed +5V 4.75V to 5.25V +24V Fixed MAP110-4001 -12V Fixed ...

  • Page 2

    ... Inrush Surge Current Internally limited by thermistor. Vin = 264 VAC (one cycle). 25 °C. Operating Frequency Switching frequency of main transformer, (fixed frequency). MCD10142 Rev. 1.0, 27-Jan-10 MAP110 AC-DC Series Data Sheet – 80W Convection Cooled, 110W Forced-Air Cooled (200 LFM) CONVECTION COOLED FORCED AIR LINE ...

  • Page 3

    ... Input to output. Leakage Current Per EN60950, 264 VAC. NOTES: 1) Minimum load is required only to meet the regulation limits of V3 and V4 and V4 are unused, no minimum load is necessary. 2) The following units meet Class B: MAP110-1005, MAP110-4000/4011/4015/4200/4300. MCD10142 Rev. 1.0, 27-Jan-10 MAP110 AC-DC Series Data Sheet MAP110-1005 ...

  • Page 4

    ... Warning time increases at reduced load levels. Thermal Add ‘T’ suffix to model number. Initiates shut-down in the event of an overtemperature Shutdown condition. Automatic recovery. MCD10142 Rev. 1.0, 27-Jan-10 MAP110 AC-DC Series Data Sheet At 100% load: At 50% load: Page MIN NOM ...

  • Page 5

    ... Power-One, Inc. TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on the date manufactured. Specifications are subject to change without notice. MCD10142 Rev. 1.0, 27-Jan-10 MAP110 AC-DC Series Data Sheet OVERALL WEIGHT: 1.3 lb (0.59 kg) Page NOTE 1 ...