AXH010A0X-SRZ Lineage Power, AXH010A0X-SRZ Datasheet - Page 14

DC/DC Converters & Regulators 0.75-3.63Vout 10A 3-5.5Vin SMT

AXH010A0X-SRZ

Manufacturer Part Number
AXH010A0X-SRZ
Description
DC/DC Converters & Regulators 0.75-3.63Vout 10A 3-5.5Vin SMT
Manufacturer
Lineage Power
Series
AXH010r
Datasheet

Specifications of AXH010A0X-SRZ

Product
Non-Isolated / POL
Output Power
36 W
Input Voltage Range
3 V to 5.5 V
Number Of Outputs
1
Output Voltage (channel 1)
0.75 V to 3.63 V
Output Current (channel 1)
10 A
Package / Case Size
SMD
Output Type
Non-Isolated
Output Voltage
0.75 V to 3.63 V
Package / Case
SMD
Lead Free Status / RoHS Status
Compliant
Data Sheet
October 2, 2009
Thermal Considerations
The power modules operate in a variety of thermal
environments; however, sufficient cooling should always
be provided to help ensure reliable operation.
Considerations include ambient temperature, airflow,
module power dissipation, and the need for increased
reliability. A reduction in the operating temperature of
the module will result in an increase in reliability. The
thermal data presented here is based on physical
measurements taken in a wind tunnel. The test set-up
is shown in Figure 34. Note that the airflow is parallel to
the long axis of the module as shown in figure 33. The
derating data applies to airflow in either direction of the
module’s long axis.
Figure 33. T ref Temperature measurement location.
The thermal reference point, T
specifications is shown in Figure 33. For reliable
operation this temperature should not exceed 115
The output power of the module should not exceed the
rated power of the module (Vo,set x Io,max).
Please refer to the Application Note “Thermal
Characterization Process For Open-Frame Board-
Mounted Power Modules” for a detailed discussion of
thermal aspects including maximum device
temperatures.
LINEAGE
Bottom View
POWER
Top View
ref
Air Flow
3.0 – 5.5Vdc Input; 0.75Vdc to 3.63Vdc Output; 10A output current
used in the
T
ref
o
C.
Austin Lynx
Heat Transfer via Convection
Increased airflow over the module enhances the heat
transfer via convection. Thermal derating curves
showing the maximum output current that can be
delivered at different local ambient temperature (T
airflow conditions ranging from natural convection and
up to 2m/s (400 ft./min) are shown in the Characteristics
Curves section.
Wind T unnel
PWBs
TM
Figure 34. Thermal Test Set-up.
SMT Non-isolated Power Modules:
flow
Air
(0.325)
x
8.3_
(3.0)
76.2_
25.4_
(1.0)
Probe Location
for measuring
airflow and
ambient
temperature
Power Module
A
) for
14

Related parts for AXH010A0X-SRZ