Specifications of BP 2101-7RG

Input Voltage
24V
Screening Level
Commercial
Operating Temperature Min Deg. C
-25C
Operating Temperature Max Deg. C
71C
Product Length (mm)
164mm
Product Depth (mm)
111mm
Product Height (mm)
19.8mm
Mounting Style
Din-Rail
Pin Count
15
Number Of Outputs
2
Lead Free Status / RoHS Status
Compliant
Parallel and Series Connection
The first outputs of power trains with equal nominal output
voltage can be connected in parallel. Where available, we
recommend ordering of option T.
Any output can be connected in series with any other output.
If the main and the tracking output of the same power train are
connected in series, consider that the effect of the R-input is
doubled.
Fig. 9
Series connection of double-output models. Sense lines
connected at the connector.
BCD20010-G Rev AC, 26-Aug-09
Notes:
• If a tracking output is not used, connect it in parallel to the
• Connection of several outputs in parallel should include
• The maximum output current of a serial-connected outputs is
respective regulated main output.
measures to approximate all output currents. 3.3 and 5 V
outputs with option T have current-share pins (T or T1), which
must be interconnected. For other outputs, the load lines
should exhibit similar resistance. Parallel connection of
regulated
recommended.
limited by the output with the lowest current limit.
+
+
R
outputs
p
i
26
22
24
30
32
26
24
30
28
22
28
32
®
without
Double-output
Double-output
Out OK+
Out OK –
Vi+
Vi–
Out OK+
Out OK –
Vi+
Vi–
i
i
model
model
R1
R1
such
16
16
Vo1+
Vo2+
Vo1+
Vo1–
Vo2–
Vo1–
Vo2–
Vo2+
S2+
S2–
S2+
S2–
S1+
S1–
S1+
S1–
JM033
precautions
18
20
10
12
14
10
12
14
18
20
6
4
6
8
8
4
is
Page 11 of 25
not
Parallel operation of two double-output converters with
series-connected outputs is shown in fig. 10. The link
between the T1 pins ensures proper current sharing, even
though only the first outputs are influenced by T1. Sense
lines are connected directly at the connector, and load lines
have equal length and section.
Fig. 10
Parallel operation of 2 double-output converters with
series-connected outputs.
Redundant Systems
An example of a redundant system using converters with 2
regulated ouputs (xP2020) is shown in fig. 11. Load 1 is
powered with 5.1 V and load 2 with 12 V.
The converters are separated with ORing diodes. If one
converter fails, the remaining one still delivers the power to
the loads. If more power is needed, the system may be
extended to more parallel converters (n+1 redundancy).
Current sharing of the 5.1 V outputs is ensured by the
interconnected T1 pins, whereas the sense lines are
• Rated output voltages above 48 V (SELV = Safety Extra Low
Voltage) require additional safety measures in order to comply
with international safety requirements.
+
+
R
90 – 194 Watt DC-DC Converters
p
i
26
22
30
32
22
24
30
32
24
28
26
28
Double-output
Double-output
Out OK+
Out OK –
Vi+
Vi–
Out OK+
Out OK –
Vi+
Vi–
i
i
model
model
P Series Data Sheet
Vo2+
Vo2+
Vo1+
Vo1–
Vo1+
Vo1–
Vo2–
Vo2–
06158b
S2+
S2–
S2+
S2–
S1+
S1–
S1+
S1–
T1
T1
14
16
18
10
12
14
16
18
10
12
20
20
8
6
4
8
6
4
www.power-one.com

Related parts for BP 2101-7RG