8-1393792-5 TE Connectivity, 8-1393792-5 Datasheet - Page 297

Electromechanical Relay DPDT 3A 5VDC 168Ohm Through Hole

8-1393792-5

Manufacturer Part Number
8-1393792-5
Description
Electromechanical Relay DPDT 3A 5VDC 168Ohm Through Hole
Manufacturer
TE Connectivity
Type
Signal Relayr
Datasheets

Specifications of 8-1393792-5

Contact Arrangement
DPDT
Dc Coil Voltage
5 V
Coil Current
29.76 mA
Mounting
Through Hole
Relay Construction
Non-Latching
Coil Voltage Dc
5V
Contact Form
2 Form C
Voltage Rating (vdc)
220V
Voltage Rating (vac)
250V
Dropout Volt (min)
0.25VDCV
Coil Resistance
168Ohm
Pick-up Voltage (max)
4VDC
Maximum Power Rating
60W/125VA
Operate Time
5ms
Contact Current Rating
3A
Contact Material
AgNi/Au
Coil Suppression Diode
No
Push To Test Button
No
Led Indicator
No
Seal
Unsealed
Product Height (mm)
11mm
Product Depth (mm)
10mm
Product Length (mm)
20.2mm
Operating Temp Range
-25C to 85C
Pin Count
8
Mounting Style
Through Hole
Termination Style
PC Pin
Package / Case
DIP
Lead Free Status / Rohs Status
Compliant
Features
• Contact ratings to 50 amps.
• Magnetic blowouts available for switching DC loads.
• Arrangements to DPDT.
• SPDT auxiliary switch available.
• Replaces PR series.
Contact Data @ 25°C
Arrangements: Available to 2 Form C (DPDT). See ordering information.
Ratings: See UL contact rating table.
Minimum Rating: 1A @ 12 VAC/VDC.
Material: Silver and silver-cadmium oxide standard. Other materials
Expected Life: 100,000 operations at rated loads @25°C. Life increases at
UL/CSA Contact Ratings
PRD 1, 3 or 5
PRD 1, 3 or 5
PRD 7 or 11
PRD 7 or 11
PRD 3,7 or 11
PRD3AP4
PRD3DP4
DC Factory Contact Ratings
Dimensions are shown for
reference purposes only.
UL Recognized Load/Life Parameters for 50 Amp PRD
Note: Any PRD relay deviating electrically or physically from the standard models in the table is
PRD3AR4
PRD3DR4
Type
Type
not UL or CSA listed. All horsepower ratings are for single phase motors.
Type
available for special applications.
50 Amps, 277VAC max., General Purpose
30 Amps, 277VAC max., Ballast
15 Amps, 277VAC max., Tungsten
102 LRA, 17 FLA, 240VAC
120 LRA, 20 FLA, 120VAC
1.5 HP at 120VAC
3 HP at 240VAC
reduced loads or with appropriate arc suppression.
Contact Ratings
AG
AG
AH
AC
AY
AY
AJ
Supply
Contact Ratings
60 Amps, 28VDC Res.
30 Amps, 125VDC Res.
DG
DG
DC
DY
DY
DH
DJ
Dimensions are in inches over
(millimeters) unless otherwise
specified.
Contact Ratings
25 amps @ 277VAC
1 HP at 120VAC
2 HP at 250VAC
10 amps at 600VAC
7 amps at 50VDC Res.
30 amps at 277VAC Res.
1.5 HP at 120VAC
2HP at 250VAC
10 amp at 600VAC
25 amps at 240VAC
20 amps at 277VAC
1HP at 120VAC
2HP at 250VAC
7 amps at 50VDC Res.
10 amps at 600VAC
30 amps at 240VAC
20 amps at 277VAC
1.5 HP at 120VAC
2 HP at 250VAC
10 amps at 600VAC
20 amp at 125VDC
1/3 HP at 125VDC
Minimum Life
100,000 Cycles
6,000 Cycles
6,000 Cycles
30,000 Cycles
30,000 Cycles
30,000 Cycles
30,000 Cycles
Catalog 1308242
Issued 3-03
PRD
10 to 50 Amp Heavy Duty
AC or DC Power Relay
Users should thoroughly review the technical data before selecting a product
part number. It is recommended that users also seek out the pertinent approvals
files of the agencies/laboratories and review them to ensure the product meets
the requirements for a given application.
Auxiliary Snap-Action Switch
Arrangements: 1 Form C (SPDT).
Rating: 5 amps at 120VAC, 60 Hz. @ 25°C.
Material: Silver.
Initial Dielectric Strength
Initial Breakdown Voltage: 2,000V rms minimum between all elements
Coil Data @ 25°C
Voltage: From 6 to 220VDC, and 6 to 480VAC.
Resistance: See coil data table.
Nom. Power: DC coils: -2.0 watts @ 25°C.
Max Power: DC coils: - 8.0 watts @ 25°C.
Duty Cycle: Continuous.
Initial Insulation Resistance: 100 megohms, minimum.
Coil Data
Nominal Resistance Nominal DC Nominal
Operate Data @ +25°C
Must-Operate Voltage: DC: 75% of nominal voltage @ 25°C.
Environmental Data
Temperature Range:
Mechanical Data
Mounting: Two .187”(4.75mm) diameter holes on 1.875” (47 .63mm)
Termination: See ordering information tables for various options.
Enclosure: Metal dust cover, 35D013, available. Order separately.
Weight: 10 oz. (284g) approximately.
Specifications and availability
subject to change.
Volts
220
110
24
12
6
File E22575 (Models With All Screw Terminals)
File E22575 (All Others)
File 15734
File 1949 (Q. C. Terminal models only)
“DY” and “DG”
±10%@ 25°C
In Ohms
centers.
6050
Use 110V relay with
approx. 6 ,000 ohm
5W wire-wound
resistor in series.
series
DC Coils
288
18
71
AC coils: - 9.8VA @ 25°C.
AC: -55°C to +45°C.
DC: -55°C to +80°C.
Current In
Milliamps
333
169
AC: 85% of nominal voltage @ 25°C.
84
18.2
and ground. (2,200V rms on 600V ratings.)
120
240
480
Volts
12
24
6
AC Coils (50-60Hz.)
±15%@ 25°C
“AY” and “AG”
DC Resis.
In Ohms
1200
4500
290
12.0
3.2
www.tycoelectronics.com
Technical support:
Refer to inside back cover.
.86
Nominal AC
Current In
Milliamps
1600
820
410
85
43
22
P&B
811

Related parts for 8-1393792-5