ADF4360-6BCPRL7 Analog Devices Inc, ADF4360-6BCPRL7 Datasheet - Page 17

IC INTEG SYNTH/VCO 24-LFCSP T/R

ADF4360-6BCPRL7

Manufacturer Part Number
ADF4360-6BCPRL7
Description
IC INTEG SYNTH/VCO 24-LFCSP T/R
Manufacturer
Analog Devices Inc
Type
Fanout Distribution, Integer N Synthesizer (RF)r
Datasheet

Specifications of ADF4360-6BCPRL7

Rohs Status
RoHS non-compliant
Pll
Yes
Input
CMOS
Output
Clock
Number Of Circuits
1
Ratio - Input:output
1:2
Differential - Input:output
No/No
Frequency - Max
1.25GHz
Divider/multiplier
Yes/No
Voltage - Supply
3 V ~ 3.6 V
Operating Temperature
-40°C ~ 85°C
Mounting Type
Surface Mount
Package / Case
24-LFCSP
Frequency-max
1.25GHz
For Use With
EVAL-ADF4360-6EBZ1 - BOARD EVALUATION FOR ADF4360-6
Hardware Power-Up/Power-Down
If the part is powered down via the hardware (using the CE pin)
and powered up again without any change to the N counter
register during power-down, the part locks at the correct fre-
quency because the part is already in the correct frequency
band. The lock time depends on the value of capacitance on the
C
pacitance of 440 nF on this pin enables lock times of <600 µs.
The N counter value cannot be changed while the part is in
power-down because the part may not lock to the correct fre-
quency on power-up. If it is updated, the correct programming
sequence for the part after power-up is to the R counter latch,
followed by the control latch, and finally the N counter latch,
with the required interval between the control latch and N
counter latch, as described in the Initial Power-Up section.
N
pin, which is <5 ms for 10 µF capacitance. The smaller ca-
Rev. A | Page 17 of 24
Software Power-Up/Power-Down
If the part is powered down via the software (using the control
latch) and powered up again without any change to the N
counter latch during power-down, the part locks at the correct
frequency because the part is already in the correct frequency
band. The lock time depends on the value of capacitance on the
C
pacitance of 440 nF on this pin enables lock times of <600 µs.
The N counter value cannot be changed while the part is in
power-down because the part may not lock to the correct fre-
quency on power-up. If it is updated, the correct programming
sequence for the parts after power-up is to the R counter latch,
followed by the control latch, and finally the N counter latch,
with the required interval between the control latch and N
counter latch, as described in the Initial Power-Up section.
N
pin, which is <5 ms for 10 µF capacitance. The smaller ca-
ADF4360-6