S-35190A-J8T1G Seiko Instruments, S-35190A-J8T1G Datasheet - Page 13

IC REAL TIME CLOCK 3WIRE 8-SOP

S-35190A-J8T1G

Manufacturer Part Number
S-35190A-J8T1G
Description
IC REAL TIME CLOCK 3WIRE 8-SOP
Manufacturer
Seiko Instruments
Type
Clock/Calendarr
Datasheet

Specifications of S-35190A-J8T1G

Time Format
HH:MM:SS (12/24 hr)
Date Format
YY-MM-DD-dd
Interface
3-Wire Serial
Voltage - Supply
1.3 V ~ 5.5 V
Operating Temperature
-40°C ~ 85°C
Mounting Type
Surface Mount
Package / Case
8-SOP
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Memory Size
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
S-35190A-J8T1G
Manufacturer:
SEIKO
Quantity:
2 246
Part Number:
S-35190A-J8T1G
Manufacturer:
SEIKO
Quantity:
10 000
Part Number:
S-35190A-J8T1G
Manufacturer:
SEIKO
Quantity:
20 000
Company:
Part Number:
S-35190A-J8T1G
Quantity:
1 822
Rev.3.0
2. Status register 1
B0 : POC
B1 : BLD
B2 : INT2, B3 : INT1
B4 : SC1, B5 : SC0
B6 :
B7 : RESET
Status register 1 is a 1-byte register that is used to display and set various modes. The bit configuration is shown below.
This flag is used to confirm whether the power is on. The power-on detection circuit operates at power-on and B0 is
set to “1”. This flag is Read-only. Once it is read, it is automatically set to “0”. When this flag is “1”, be sure to initialize.
Regarding the operation after power-on, refer to “ Power-on Detection Circuit and Register Status”.
This flag is set to “1” when the power supply voltage decreases to the level of detection voltage (V
can detect a drop in the power supply voltage. This flag is set to “1” once, is not set to “0” again even if the power
supply increases to the level of detection voltage (V
to initialize. Regarding the operation of the power supply voltage detection circuit, refer to “
Voltage Detection Circuit”.
This flag indicates the time set by alarm and when the time has reached it. This flag is set to “1” when the time that
users set by using the alarm interrupt function has come. The INT1 flag in “1” at alarm 1 interrupt mode, the INT2 flag
in “1” at alarm 2 interrupt mode. Set “0” in INT1AE (B5 in the status register 2) or in INT2AE (B1 in the status register
2) after reading “1” in the INT1 flag or in the INT2 flag. This flag is Read-only. This flag is read once, is set to “0”
automatically.
These flags are SRAM type registers, they are 2 bits as a whole, can be freely set by users.
This flag is used to set 12-hour or 24-hour expression.
The internal IC is initialized by setting this bit to “1”. This bit is Write-only. It is always “0” when Read. When applying
the power supply voltage to the IC, be sure to write “1” to this bit to initialize the circuit. Regarding each status of data
after initialization, refer to “ Register Status After Initialization”.
0 : 12-hour expression
1 : 24-hour expression
12
_00
/
RESET
24
B7
W
12 / 24
R/W
B6
R/W
SC0
B5
Figure 15 Status Register 1
Seiko Instruments Inc.
R/W
SC1
B4
DET
) or more. This flag is Read-only. When this flag is “1”, be sure
INT1
B3
R
R
W
R/W
:
:
:
INT2
B2
R
Read
Write
Read/Write
3-WIRE REAL-TIME CLOCK
BLD
B1
R
POC
B0
R
Low Power Supply
DET
S-35190A
) or less. Users
13