S-35190A-J8T1G Seiko Instruments, S-35190A-J8T1G Datasheet - Page 15

IC REAL TIME CLOCK 3WIRE 8-SOP

S-35190A-J8T1G

Manufacturer Part Number
S-35190A-J8T1G
Description
IC REAL TIME CLOCK 3WIRE 8-SOP
Manufacturer
Seiko Instruments
Type
Clock/Calendarr
Datasheet

Specifications of S-35190A-J8T1G

Time Format
HH:MM:SS (12/24 hr)
Date Format
YY-MM-DD-dd
Interface
3-Wire Serial
Voltage - Supply
1.3 V ~ 5.5 V
Operating Temperature
-40°C ~ 85°C
Mounting Type
Surface Mount
Package / Case
8-SOP
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Memory Size
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
S-35190A-J8T1G
Manufacturer:
SEIKO
Quantity:
2 246
Part Number:
S-35190A-J8T1G
Manufacturer:
SEIKO
Quantity:
10 000
Part Number:
S-35190A-J8T1G
Manufacturer:
SEIKO
Quantity:
20 000
Company:
Part Number:
S-35190A-J8T1G
Quantity:
1 822
Rev.3.0
4. INT register 1 and INT register 2
The INT register 1 is to set up the output of user-set frequency, or to set up alarm 1 interrupt. The INT register 2 is for
setting alarm 2 interrupt. Users are able to switch the output mode by using the status register 2. If selecting to use the
output mode for alarm interrupt by status register 2; this register works as the alarm-time data register. In the INT register
1, if selecting the output of user-set frequency by status register 2; this register works as the data register to set the
frequency for clock output. From the INT pin, a clock pulse and alarm interrupt are output, according to the or-condition
that these two registers have.
(1)
INT register 1
Users can set the alarm time (the data of day of the week, hour, minute) by using the INT register 1 and 2 which are
3-byte data registers. The configuration of register is as well as the data register of day of the week, hour, minute, in
the real-time data register; is expressed by the BCD code. Do not set a nonexistent day. Users are necessary to set
up the alarm-time data according to the 12/24 hour expression that they set by using the status register 1.
The INT register 1 has A1WE, A1HE, A1mE at B0 in each byte. It is possible to make data valid; the data of day of the
week, hour, minute which are in the corresponded byte; by setting these bits to “1”. This is as well in A2WE, A2HE,
A2mE in the INT register 2.
Setting example: alarm time “7:00 pm” in the INT register 1
(a) 12-hour expression (status register 1 B6 = 0)
(b) 24-hour expression (status register 1 B6 = 1)
Alarm interrupt
_00
B7
B7
W1
H1
m1
B7
Day of the week
Day of the week
set up 7:00 PM
Data written to INT register 1
*1. Don’t care (Both of 0 and 1 are acceptable).
set up 19:00 PM
Data written to INT register 1
*1. Don’t care (Both of 0 and 1 are acceptable).
*2. Set up
W2
m2
H2
W4
m4
H4
Minute
Minute
Hour
Hour
Figure 17 INT Register 1 and INT Register 2 (Alarm-Time Data)
m8
H8
AM
0
/
B7
B7
m10 m20 m40
PM
H10
1
0
1
0
*1
*1
0
flag along with the time setting.
H20
0
1
0
0
0
*1
*1
AM/
PM
Seiko Instruments Inc.
0
1
0
0
0
*1
*1
A1mE
A1WE
A1HE
B0
B0
B0
0
0
1
0
*1
*1
INT register 2
0
0
1
0
*1
*1
H1
W1
m1
B7
B7
B7
0
0
0
0
*1
*1
m2
W2
H2
1
3-WIRE REAL-TIME CLOCK
1
0
0
*1
*1
*2
m4
W4
H4
B0
B0
H8
m8
0
1
1
0
1
1
0
m10 m20 m40
H10
0
H20
0
AM/
PM
S-35190A
0
A2HE
A2mE
A2WE
B0
B0
B0
15

Related parts for S-35190A-J8T1G