AD5272BRMZ-20 Analog Devices Inc, AD5272BRMZ-20 Datasheet - Page 22

IC DGTL POT 20K 1024POS 10MSOP

AD5272BRMZ-20

Manufacturer Part Number
AD5272BRMZ-20
Description
IC DGTL POT 20K 1024POS 10MSOP
Manufacturer
Analog Devices Inc
Datasheet

Specifications of AD5272BRMZ-20

Design Resources
Compact, Low Cost, 5 V, Variable Gain, Noninverting Amplifier Using AD5270/2 and AD8615 (CN0161) Compact, Low Cost, 5 V, Variable Gain, Inverting Amplifier Using AD5270/2 and AD8615(CN0168)
Taps
1024
Resistance (ohms)
20K
Number Of Circuits
1
Temperature Coefficient
5ppm/°C
Memory Type
Non-Volatile
Interface
I²C, 2-Wire Serial
Voltage - Supply
2.7 V ~ 5.5 V, ±2.5 V ~ 2.75 V
Operating Temperature
-40°C ~ 125°C
Mounting Type
Surface Mount
Package / Case
10-MSOP, Micro10™, 10-uMAX, 10-uSOP
Resistance In Ohms
*
End To End Resistance
20kohm
Track Taper
Linear
Resistance Tolerance
± 1%
No. Of Steps
1024
Supply Voltage Range
2.7V To 5.5V
Control Interface
I2C, Serial
No. Of Pots
Single
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
AD5272BRMZ-20
Manufacturer:
AD
Quantity:
1 001
Part Number:
AD5272BRMZ-20
Manufacturer:
ADI/亚德诺
Quantity:
20 000
Company:
Part Number:
AD5272BRMZ-20
Quantity:
6 000
Table 13. Write and Read to RDAC and 50-TP memory
DIN
0x1C03
0x0500
0x0800
0x0C00
0x1800
0x0000
0x1419
0x2000
0x0000
1
Table 14. Control Register Bit Map
DB9
0
Table 15. Control Register Description
Bit Name
C0
C1
C2
C3
1
Table 16. Memory Map
Command Number
5
1
X is don’t care.
Wiper position is frozen to the last value programmed in the 50-TP memory. Wiper freezes to midscale if 50-TP memory has not been previously programmed.
X is don’t care.
0x1C03
0xXXXX
SDO
0xXXXX
0x0500
0x100
0x0C00
0xXX19
0x0000
0x0100
DB8
0
1
Action
Enable update of wiper position and 50-TP memory contents through digital interface.
Write 0x100 to the RDAC register, wiper moves to ¼ full-scale position.
Prepare data read from RDAC register.
Stores RDAC register content into 50-TP memory. 16-bit word appears out of SDO, where last 10-bits contain the
contents of the RDAC Register 0x100.
Prepare data read of last programmed 50-TP memory monitor location.
NOP Instruction 0 sends a 16-bit word out of SDO, where the six LSBs last 6-bits contain the binary address of the last
programmed 50-TP memory location, for example, 0x19 (see Table 16).
Prepares data read from Memory Location 0x19.
Prepare data read from the control register. Sends a 16-bit word out of SDO, where the last 10-bits contain the contents
of Memory Location 0x19.
NOP Instruction 0 sends a 16-bit word out of SDO, where the last four bits contain the contents of the control register.
If Bit C3 = 1, fuse program command successful.
Description
50-TP program enable
1 = enable device for 50-TP program
RDAC register write protect
0 = wiper position frozen to value in 50-TP memory (default)
1 = allow update of wiper position through a digital interface
Resistor performance enable
1 = RDAC resistor tolerance calibration disabled
50-TP memory program success bit
1 = fuse program command successful
0 = 50-TP program disabled (default)
0 = RDAC resistor tolerance calibration enabled (default)
0 = fuse program command unsuccessful (default)
D9
X
X
X
X
X
X
X
X
X
X
DB7
0
D8
X
X
X
X
X
X
X
X
X
X
D7
X
X
X
X
X
X
X
X
X
X
DB6
0
D6
0
0
0
0
0
0
0
0
0
0
Data Byte [DB9:DB8]
D5
0
0
0
0
0
0
0
0
1
1
DB5
0
D4
0
0
0
0
0
0
1
1
0
1
Rev. C | Page 22 of 28
D3
0
0
0
0
0
1
0
1
1
0
1
DB4
0
D2
0
0
0
0
1
0
1
1
0
0
D1
0
0
1
1
0
1
0
1
0
1
1
DB3
C3
0
1
0
1
0
0
0
0
0
0
D0
Register Contents
Reserved
1st programmed wiper location (0x01)
2nd programmed wiper location (0x02)
3rd programmed wiper location (0x03)
4th programmed wiper location (0x04)
10th programmed wiper location (0xA)
20th programmed wiper location (0x14)
30th programmed wiper location (0x1E)
40th programmed wiper location (0x28)
50th programmed wiper location (0x32)
DB2
C2
AD5272/AD5274
DB1
C1
DB0
C0

Related parts for AD5272BRMZ-20