Specifications of APC12J03-9MAL

Number Of Outputs
1
Output Current
12A
Input Voltage
3.3V
Output Voltage
0.9V
Screening Level
Industrial
Product Length (mm)
33.02mm
Product Depth (mm)
16mm
Mounting Style
Surface Mount
Pin Count
7
Package / Case
SMT
Lead Free Status / Rohs Status
Compliant
Mechanical Specifications (continued)
RECOMMENDED LOCATION FOR PICK AND PLACE
The flat top surface of the large inductor (topside of the board) provides a versatile and convenient way of picking up the
module (see Figure 56). A 6-7mm outside diameter nozzle from a conventional SMD machine is recommended to attain
maximum vacuum pick-up. Nozzle travel and rotation speed should be controlled to prevent this off-centered picked-up
module from falling off the nozzle. The use of vision recognition systems for placement accuracy will be very helpful.
REFLOW NOTES / RECOMMENDATIONS
1. Refer to the recommended Reflow Profile per
2. The module is recommended for topside
3. In the event that the module needs to be
MODULE MARKINGS / LABELS
Marking shall be permanent and legible.
Please refer to Figure 58 for the module
marking/ label detail.
MODEL: APC12 SERIES
JANUARY 6, 2002 REVISION A (PRELIMINARY)
Figure 57. Profile parameters exceeding the
recommended maximums may result to
permanent damage to the module.
reflow process to the host card. For other
orientations, contact factory.
desoldered from the host card, some pins
may be detached from the module.
Technical Reference Notes
APC12 Centauri II
Note
MMM
FFF
Note
YYWW
D
PP
LL
Note
1
2
3:
240
220
200
180
160
140
120
100
80
60
40
20
Barcode
0
0
Model No
Option
Year / Work Week
Day of Week
nth Panel of the day
Location in the panel
6 & 7 characters / line
Code 128, 32CPI
0.070" Height
183° ° ° ° C
110° ° ° ° C
30
RECOMMENDED REFLOW PROFILE
Figure 57. Recommended Reflow Profile.
Figure 58. Module Label
60
< 4° ° ° ° C /sec
SLOPE
90
PRE-HEAT ZONE
PEAK TEMPERATURE
120 - 180 sec
200° ° ° ° C - 230° ° ° ° C
120
TIME (seconds)
150
180
APC12MMMFFF
YYWWDPPLL
210
REFLOW
< 80 sec
ZONE
SHEET 21 OF 23
240
270
300

Related parts for APC12J03-9MAL