H5CX-A-N AC100-240 Omron Automation, H5CX-A-N AC100-240 Datasheet - Page 34

no-image

H5CX-A-N AC100-240

Manufacturer Part Number
H5CX-A-N AC100-240
Description
Relay; E-Mech; Timing; Multi-Function; Cur-Rtg 5A; Ctrl-V 100-240AC; REPL:H5CX-AAC1002
Manufacturer
Omron Automation
Type
Timerr
Datasheet

Specifications of H5CX-A-N AC100-240

Brand/series
H5CX
Connection Type
Screw Terminals
Contact Form
5 A at 250VAC/30 VDC
Dimensions
58H x 48W x 98.5D
Display Type
7 Segment LCD
Function
Multifunction Digital Timer
Input Type
Signal, Reset and Gate
Ip Rating
IP66
Mounting Type
Flush
Number Of Inputs
3
Number Of Outputs
1
Output Type
SPDT
Primary Type
Digital Timer
Voltage, Supply
100-240 VAC
34
H5CX-B@-N
Characteristics
Applicable Standards
I/O Functions
Response Delay Time When Resetting (Transistor Output)
The following table shows the delay from when the reset signal is input until the output is turned OFF.
Accuracy of operating time
and setting error
(including temperature and
voltage influences)
Insulation resistance
Dielectric strength
Impulse withstand voltage
Noise immunity
Static immunity
Vibration
resistance
Shock
resistance
Weight
Approved safety standards
EMC
Inputs
Outputs
Minimum reset signal width
Start signal
Reset
Gate
Forecast value
setting
Absolute value
setting
20 ms
1 ms
Destruction
Malfunction
Destruction
Malfunction
Control output (OUT2)
Forecast output (OUT1)
Control output 2 (OUT2)
Control output 1 (OUT1)
Power-ON start: ±0.01% ±50 ms max. (See note 1.)
Signal start: ±0.005%±0.03 ms max. (See note 1.)
Signal start for transistor output model: ±0.005%±3 ms max. (See note 1 and 2.)
If the set value is within the sensor waiting time at startup the control output of the H5CX will not turn ON until the sensor waiting
time passes.
Note: 1. The values are based on the set value.
100 MΩmin. (at 500 VDC) between current-carrying terminal and exposed non-current-carrying metal parts
2,000 VAC, 50/60 Hz for 1 min between current-carrying metal parts and non-current-carrying metal parts
1,000 VAC, 50/60 Hz for 1 min between control output, power supply, and input circuit
1.0 kV (between power terminals)
1.5 kV (between current-carrying terminal and exposed non-current-carrying metal parts)
±480 V (between power terminals) and ±600 V (between input terminals), square-wave noise by noise simulator
(pulse width: 100 ns/1 µs, 1-ns rise)
Destruction: 15 kV
Malfunction: 8 kV
10 to 55 Hz with 0.75-mm single amplitude in three directions for 2 h each
10 to 55 Hz with 0.35-mm single amplitude in three directions for 10 min each
300 m/s
100m/s
Approx. 105 g (Timer only)
UL508/Listing, CSA C22.2 No. 14, conforms to EN 61812-1 (pollution degree 2/overvoltage category III)
Conforms to VDE0106/P100 (finger protection).
(EMI)
Emission Enclosure:
(EMS)
Immunity ESD:
Immunity RF-interference:
Immunity Conducted Disturbance:
Immunity Burst:
Immunity Surge:
2. The value is applied for a minimum pulse width of 1 ms.
2
2
in three directions, three cycles
in three directions, three cycles
Output delay time
0.8 to 1.2 ms
15 to 25 ms
Starts timing.
• Resets present value. (The present value returns to 0.)
• Timing stops and control output turns OFF while reset input is ON.
• Reset indicator is lit while reset input is ON.
Inhibits timer operation.
Turns ON when the present value reaches the set value.
Turns ON when the present value reaches the forecast value.
Turns ON when the present value reaches set value 2.
Turns ON when the present value reaches set value 1.
(Reference value)
EN61812-1
EN55011 Group 1 class A
EN61812-1
EN61000-4-2: 6 kV contact discharge (level 2)
EN61000-4-3: 10 V/m (Amplitude-modulated, 80 MHz to 1 GHz) (level 3);
EN61000-4-6: 10 V (0.15 to 80 MHz) (level 3)
EN61000-4-4: 2 kV power-line (level 3);
EN61000-4-5: 1 kV line to lines (power and output lines) (level 3);
8 kV air discharge (level 3)
10 V/m (Pulse-modulated, 900 MHz 5 MHz) (level 3)
1 kV I/O signal-line (level 4)
2 kV line to ground (power and output lines) (level 3)

Related parts for H5CX-A-N AC100-240