ES-UA-5A BANNER ENGINEERING, ES-UA-5A Datasheet

no-image

ES-UA-5A

Manufacturer Part Number
ES-UA-5A
Description
Sensor, E-stop Module, output 6A,
Manufacturer
BANNER ENGINEERING
Type
Safetyr
Datasheets

Specifications of ES-UA-5A

Contact Form
4-NO/1-NC
Dimensions
45mmW×84mmH×118mmD
Enclosure Rating
IP20
Ip Rating
IP20
Mounting Type
DIN Rail
Number Of Outputs
8
Output Type
Relay
Power, Rating
4 W
Primary Type
Controller
Standards
UL, CSA, CE
Voltage, Supply
115/12 to 24 VAC/VDC
Coil Voltage Vdc Nom
24V
Coil Resistance
250ohm
Contact Current Max
6A
Contact Voltage Ac Nom
24V
Contact Voltage Dc Nom
250V
Contact Configuration
SPST-NC
No. Of Poles
1
Relay Mounting
DIN Rail
Lead Free Status / Rohs Status
RoHS Exempt Product
For Use With
Emergency Stop
P/N 122365 rev. C
Original Instructions
This Safety Module is not a point-of-operation guarding device, as defined by OSHA regulations. It is necessary
to install point-of-operation guarding devices, such as safety light curtains and/or hard guards, to protect personnel
from hazardous machinery. Failure to install point-of-operation guards on hazardous machinery can result
in a dangerous condition which could lead to serious injury or death.
Model
ES-UA-5A
ES-VA-5A
WARNING . . . Not a Point-of-Operation Guarding Device
Emergency
Stop
Devices
29YL
Supply Voltage
12-24V dc
12-24V dc
115V ac
230V ac
or
or
Monitors emergency stop devices, such as palm buttons and rope/cable
pulls, and positive-opening safety switches used for guard/gate interlock-
ing
The safety inputs can monitor:
Four normally open output switching channels for connection to control-
reliable power interrupt circuits and three auxiliary output channels
Automatic reset or monitored manual reset
Design complies with standards ANSI B11.19, UL991, ISO 13850
(EN418), and ISO 13849-1 (EN954-1) (Safety Category 4)
For use in functional stop category 0 applications per ANSI NFPA 79
and IEC/EN60204-1
6 amp safety output contacts; 5 amp aux. output contacts
Plug-in terminal blocks
Outputs
Hard/relay contacts in a dual-channel hookup using terminals S11-S12
and S21-S22, or
A +24V dc source switched by hard/relay contacts in single-channel
hookup
ES-UA-5A and ES-VA-5A E-Stop Safety
Modules
Model ES-UA-5A for 12-24V dc/115V ac operation; Model ES-
VA-5A for 12-24V dc/230V ac operation
4 Normally open safety
1 Normally closed aux.
2 Solid-state aux.
5/2010
Output Rating
N.O. Safety Outputs: 6 A
N.C. Aux. Outputs: 5 A
SS Aux. Outputs: 100 mA
0 122365 1

Related parts for ES-UA-5A

ES-UA-5A Summary of contents

Page 1

... P/N 122365 rev. C ES-UA-5A and ES-VA-5A E-Stop Safety Modules Model ES-UA-5A for 12-24V dc/115V ac operation; Model ES- VA-5A for 12-24V dc/230V ac operation Monitors emergency stop devices, such as palm buttons and rope/cable pulls, and positive-opening safety switches used for guard/gate interlock- ...

Page 2

... ISO 13849-1 (EN954-1), Safety of Machinery – Related Parts of Control Systems: Part 1 General Principles for Design ISO 13850 (EN418), Emergency Stop Devices Contact: Global Engineering Documents, 15 Inverness Way East, Englewood, CO 80112-5704, Tel.: 800-854- 7179 2 Banner Engineering Corp. - Minneapolis, MN USA - www.bannerengineering.com ES-UA-5A and ES-VA-5A E-Stop Safety Modules Tel: 763.544.3164 P/N 122365 rev. C ...

Page 3

... ES-UA-5A and ES-VA-5A E-Stop Safety Modules An Emergency Stop Safety Module is used to increase the control reliability of an emergency stop circuit. As shown in the hookup drawings, the models ES-UA-5A and ES-VA-5A E-Stop Safety Modules (the Safety Modules) are designed to monitor a 1- channel or 2-channel E-stop switch. A 2-channel E-stop switch has two electrically isolated contacts ...

Page 4

... The wire rope should be easily accessible and visible along its entire length. Markers or flags may be fixed on the rope to increase its visibility. Mounting points, including support points, must be rigid. The rope should be free of friction at all supports. Pulleys are recommended. 4 Banner Engineering Corp. - Minneapolis, MN USA - www.bannerengineering.com ES-UA-5A and ES-VA-5A E-Stop Safety Modules Tel: 763.544.3164 P/N 122365 rev. C ...

Page 5

... This classifies the Safety Module as a functional stop "Category 0" E-stop control, as defined by ANSI NFPA 79 and IEC/EN 60204-1. The Safety Module is powered by either a 12-24V dc supply supply (115V ac, model ES-UA-5A, or 230V ac, model ES-VA-5A) at 7VA. The safety inputs can be connected to: A +24V dc source that is switched by a hard/relay contact in single-channel hookup configuration, or Hard/relay contacts in a dual-channel hookup configuration using terminals S11-S12 and S21-S22 ...

Page 6

... Multiple switches connected to one Safety Module must be series connected (see figure at right and the warning, Multiple Switching Devices). 6 Banner Engineering Corp. - Minneapolis, MN USA - www.bannerengineering.com ES-UA-5A and ES-VA-5A E-Stop Safety Modules E-Stop E-Stop S11 S21 S22 S12 Figure 2: Series connection of multiple E-stop switches Tel: 763 ...

Page 7

... ES-UA-5A and ES-VA-5A E-Stop Safety Modules WARNING . . . Multiple Safety Devices When two or more safety devices are used, each device must be individually actuated, causing a STOP or open-contact condition, then reset/rearmed and the Safety Module reset (if using manual reset mode). This allows the monitoring circuits to check each device and its wiring to detect faults. Failure to test each device in- dividually in this manner could result in undetected faults and create an unsafe condition which could result in serious injury or death ...

Page 8

... Banner Engineering Corp. - Minneapolis, MN USA - www.bannerengineering.com ES-UA-5A and ES-VA-5A E-Stop Safety Modules Tel: 763.544.3164 P/N 122365 rev. C ...

Page 9

... ES-UA-5A and ES-VA-5A E-Stop Safety Modules Hookup Drawings Auto Reset AC Power shown 115 ac or 230V ac (depending on model ES-UA-5A 115V ES-VA-5A 230V ac E-Stop Switch S11 S21 MSC1 MSC3 S22 S31 MSC Monitor S12 Contacts or Jumper for No Monitoring S32 S34 MSC2 MSC4 S33 ...

Page 10

... Y35 Outputs Power Supply Energized Fault 12-24V common Figure 5: Hookup: 1-Channel E-stop applications 10 Banner Engineering Corp. - Minneapolis, MN USA - www.bannerengineering.com ES-UA-5A and ES-VA-5A E-Stop Safety Modules Manual Reset DC Power shown +V E-Stop Switch power connections shown are valid for either B1 auto or manual reset. ...

Page 11

... ES-UA-5A and ES-VA-5A E-Stop Safety Modules Overvoltage Category II and III Installations (EN 50178 and IEC 60664-1) The Safety Module is rated for Overvoltage Category III when voltages 150V ac/dc are applied to the output relay contacts rated for Overvoltage Category II when voltages of 151V to 250V ac/dc are applied to the output relay contacts and no additional precautions are taken to attenuate possible overvoltage situations in the supply voltage ...

Page 12

... If using manual reset mode, close and then open the reset switch within 2 seconds. Verify that the machine can be restarted by normal initiation. 12 Banner Engineering Corp. - Minneapolis, MN USA - www.bannerengineering.com ES-UA-5A and ES-VA-5A E-Stop Safety Modules Initial Checkout Procedure Periodic Checkout Procedure Tel: 763.544.3164 ...

Page 13

... Pack the Module carefully. Damage which occurs in return shipping is not covered by warranty. Category Specification Supply Voltage and Current AI-A2: 115V ac (model ES-UA-5A) or 230V ac (model ES-VA-5A) ±15% , 50/60Hz BI-B2: 11V dc – 27.6V dc Power consumption: approx. 4W/7VA The Safety Module should be connected only to a SELV (safety extra-low voltage, for circuits without earth ground PELV (protected extra-low voltage, for circuits with earth ground) power supply ...

Page 14

... K2 are energized. Output at Y35 conducts (output high) when in normal operation (no lockout). Output Response Time 35 ms max. (25 ms typical) 14 Banner Engineering Corp. - Minneapolis, MN USA - www.bannerengineering.com ES-UA-5A and ES-VA-5A E-Stop Safety Modules Max. voltage: 60V Max. current: 300 mA Max. power VA) Minimum: Maximum Emergency ...

Page 15

... ES-UA-5A and ES-VA-5A E-Stop Safety Modules Category Specification Input Requirements E-stop switch: must have normally closed contacts each capable of switching 30V dc; and must be open > for a valid stop command. Maximum input resistance 250 ohms per channel @ 24V dc supply voltage. Maximum input resistance 25 ohms per channel @ 12V dc supply voltage. ...

Page 16

... Fault LED OFF Ch1 LED OFF Ch2 LED ON No fault indicated Power LED ON Fault LED OFF 16 Banner Engineering Corp. - Minneapolis, MN USA - www.bannerengineering.com ES-UA-5A and ES-VA-5A E-Stop Safety Modules 84 mm (3.3" (1.8") Troubleshooting Possible Causes / Solutions Waiting for manual reset: EDM monitoring contacts are not closed. Check MSCs. ...

Page 17

... ES-UA-5A and ES-VA-5A E-Stop Safety Modules Condition Indicator Status Ch1 LED ON Ch2 LED OFF Fault Power LED ON Fault LED ON* Ch1 and Ch2 LED flashing alter- nately Fault Power LED ON Fault LED ON* Ch1 LED OFF Ch2 LED Flashing Fault Power LED ON Fault LED ON* ...

Page 18

... Banner Engineering Corp. herewith declares that ES-UA-5A and ES-VA-5A Emergency Stop Modules for industrial control are in conformity with the provisions of the Machinery Directive (Directive 2006/42/EC), and all essential Health and Safety Requirements have been met. Download the complete EC Declaration of Conformity as a PDF file at http://www ...

Related keywords