ES-UA-5A BANNER ENGINEERING, ES-UA-5A Datasheet - Page 16

no-image

ES-UA-5A

Manufacturer Part Number
ES-UA-5A
Description
Sensor, E-stop Module, output 6A,
Manufacturer
BANNER ENGINEERING
Type
Safetyr
Datasheets

Specifications of ES-UA-5A

Contact Form
4-NO/1-NC
Dimensions
45mmW×84mmH×118mmD
Enclosure Rating
IP20
Ip Rating
IP20
Mounting Type
DIN Rail
Number Of Outputs
8
Output Type
Relay
Power, Rating
4 W
Primary Type
Controller
Standards
UL, CSA, CE
Voltage, Supply
115/12 to 24 VAC/VDC
Coil Voltage Vdc Nom
24V
Coil Resistance
250ohm
Contact Current Max
6A
Contact Voltage Ac Nom
24V
Contact Voltage Dc Nom
250V
Contact Configuration
SPST-NC
No. Of Poles
1
Relay Mounting
DIN Rail
Lead Free Status / Rohs Status
RoHS Exempt Product
For Use With
Emergency Stop
Figure 6: Dimensions — in mm (inches)
16
Condition
Module will not reset
No fault indicated
No fault indicated
No fault indicated
118.0 mm
(4.6")
Banner Engineering Corp. - Minneapolis, MN USA - www.bannerengineering.com
Indicator Status
Power LED ON
Fault LED OFF
Ch1 LED Flashing
Ch2 LED Flashing
Power LED ON
Fault LED OFF
Ch1 LED OFF
Ch2 LED OFF
Power LED ON
Fault LED OFF
Ch1 LED OFF
Ch2 LED ON
Power LED ON
Fault LED OFF
Troubleshooting
Tel: 763.544.3164
84 mm
(3.3")
ES-UA-5A and ES-VA-5A E-Stop Safety Modules
Possible Causes / Solutions
Waiting for manual reset:
E-stop button open:
Ch.1 open; Ch. 2 closed:
Ch.1 closed; Ch. 2 open:
EDM monitoring contacts are not closed. Check MSCs.
Check jumper at S32-S35 (auto reset) or S32-S33
(manual reset).
Check reset button connection.
Connector loose.
Re-arm E-stop button.
Check wiring to S11-S12.
Check switch.
Check connectors are properly seated.
Check wiring to S21-S22.
45 mm
(1.8")
P/N 122365 rev. C