H7CX-A4-N AC100-240 Omron Automation, H7CX-A4-N AC100-240 Datasheet - Page 19

no-image

H7CX-A4-N AC100-240

Manufacturer Part Number
H7CX-A4-N AC100-240
Description
Counter, Digital, Four Digit, Multifunction, 1/16 Din, 100-240VAC, Contact Ouput, Screw
Manufacturer
Omron Automation
Type
Counterr
Datasheet

Specifications of H7CX-A4-N AC100-240

Brand/series
H7CX
Connection Type
Screw Terminals
Contact Form
3 A at 250VAC/30 VDC
Dimensions
58H x 48W x 98.5D
Display Type
7 Segment LCD
Function
Multifunction Digital Counter
Input Type
Increment, Decrement, Command, Individual and Quadrature
Ip Rating
IP66
Mounting Type
Flush
Number Of Inputs
4
Number Of Outputs
1
Output Type
SPDT
Primary Type
Digital Counter
Voltage, Supply
100-240 VAC
Absolute Value Setting/Forecast Value Setting (setm)
For the 2 count output mode, an absolute value setting (abs) or
forecast value setting (ofst) can be set for set value 1.
When a forecast value is set, specify the forecast value set value (i.e.,
the deviation for the set value).
The forecast output (output 1) turns ON when the present value
reaches the forecast value.
If the forecast set value is greater than or equal to the set value, the
forecast output (output 1) will turn ON as soon as counting starts.
If the forecast value setting is used, specify the set value 2 minus the
forecast value setting for set value 1.
Set Value Upper Limit (sl-h)
Set the upper limit for the set value when it is set in run mode.
The setting can be made from 1 to 9999 for 4-digit models and from
1 to 999999 for 6-digit models.
Forecast Set Upper Limit (pl-h)
Set the upper limit for the forecast set value.
The setting can be made from 1 to 9999 for 4-digit models and from
1 to 999999 for 6-digit models.
Batch Count Upper Limit (bl-h)
Set the upper limit for the batch count value. The setting can be made
from 1 to 9999 for 4-digit models and from 1 to 999999 for 6-digit
models.
Output Allocation (otst)
When using an H7CX-AU@-N model as a 2-stage counter, the output
can be flexibly allocated to either stage 1 or 2.
The transistor output can be allocated to SV1 and the contact output
to SV2 or vice verse, as in the following tables.
H7CX-AU-N/-AUD1-N
H7CX-AUSD1-N
Key Protect Level (kypt)
Set the key protect level.
Refer to Key Protect Level on page page 36.
off
on
off
on
Forecast set value
Forecast output (OUT1)
Control output 1 (OUT1)
Control output 2 (OUT2)
Transistor (12-13)
Contact (3, 4, 5)
Transistor (12-13)
Transistor with diode (3, 4, 5)
Control output (OUT 2)
Set value 2
Set value 1
Set value
Forecast
Output 1
Output 1
value
0
0
Example: F Mode
Example: F Mode
Contact (3, 4, 5)
Transistor (12-13)
Transistor with diode (3, 4, 5)
Transistor (12-13)
Output 2
Output 2
Count value
Count value
Output ON Count Alarm Set Value (on-a)
Set the alarm value for the output ON count.
The limit can be set to between 0
(9,999,000 times). Only the underlined values are set. The alarm will
be disabled if 0 is set.
If the total ON count of the output exceeds the alarm set value, e3
will be displayed on the Timer to indicate that the output ON count
alarm value was exceeded. Refer to Self-diagnostic Function on page
page 36 for information on the e3 display.
ON Count Alarm Set Values for Outputs 1 and 2 (OUT1
and OUT2) (on1a and on2a)
Set the ON count alarm values for the outputs 1 and 2.
The limit can be set to between 0
(9,999,000 times). Only the underlined values are set. The alarm will
be disabled if 0 is set.
If the total ON count of instantaneous output 1 or 2 exceeds the alarm
set value, e3 will be displayed on the Timer to indicate that the output
ON count alarm value was exceeded. Refer to Self-diagnostic
Function on page page 36 for information on the e3 display.
Output ON Count Monitor Value (on-c)
The monitor value is only displayed. It cannot be set.
The output ON count will be 1,000 times the displayed value.
ON Count Monitor Values for Outputs 1 and 2 (OUT1 and
OUT2) (on1c and on2c)
The monitor value for output 1 or 2 is only displayed. It cannot be set.
The output ON count will be 1,000 times the displayed value.
1000 (0 times) and 9999
1000 (0 times) and 9999
H7CX-A@-N
Counter
1000
1000
19