H7CX-A4-N AC100-240 Omron Automation, H7CX-A4-N AC100-240 Datasheet - Page 52

no-image

H7CX-A4-N AC100-240

Manufacturer Part Number
H7CX-A4-N AC100-240
Description
Counter, Digital, Four Digit, Multifunction, 1/16 Din, 100-240VAC, Contact Ouput, Screw
Manufacturer
Omron Automation
Type
Counterr
Datasheet

Specifications of H7CX-A4-N AC100-240

Brand/series
H7CX
Connection Type
Screw Terminals
Contact Form
3 A at 250VAC/30 VDC
Dimensions
58H x 48W x 98.5D
Display Type
7 Segment LCD
Function
Multifunction Digital Counter
Input Type
Increment, Decrement, Command, Individual and Quadrature
Ip Rating
IP66
Mounting Type
Flush
Number Of Inputs
4
Number Of Outputs
1
Output Type
SPDT
Primary Type
Digital Counter
Voltage, Supply
100-240 VAC
52
H7CX-@-N
Safety Precautions for All H7CX Series (Common)
Do not allow pieces of metal, wire clippings, or fine
metallic shavings or fillings from installation to enter
the product. Doing so may occasionally result in
electric shock, fire, or malfunction.
Minor injury due to explosion may occasionally occur.
Do not use the Counter where subject to flammable or
explosive gas.
Fire may occasionally occur. Tighten the terminal
screws to the rated torque.
H7CX terminals: 6.55 to 7.97 lb-in (0.74 to 0.90 N·m)
P2CF Socket terminals: 4.4 lb-in (0.5 N·m)
Minor injury due to electric shock may occasionally
occur. Do not touch any of the terminals while power
is being supplied. Be sure to mount the terminal cover
after wiring.
The life expectancy of the output relay varies
considerably according to its usage. Use the output
relay within its rated load and electrical life
expectancy. If the output relay is used beyond its life
expectancy, its contacts may become fused or there may be a
risk of fire. Also, be sure that the load current does not exceed
the rated load current and when using a heater, be sure to use a
thermal switch in the load circuit.
Minor electric shock, fire, or malfunction may
occasionally occur. Do not disassemble, modify, or
repair the Counter or touch internal components.
• The panel surface of the H7CX-A/-R is water-resistant (conforming
• When mounting the Counter to a panel, tighten the two mounting
• Store the Counter at the specified temperature. If the Counter has
• Mounting the Counter side-by-side may reduce the life
• Use the Counter within the specified ranges for the ambient
• Do not use in the following locations:
• Do not use the Counter outside of the rated ranges for vibration,
• Do not use this Counter in dusty environments, in locations where
• Install the Counter well away from any sources of static electricity,
to NEMA4, IP66, UL Type 4X (Indoor Use Only). To protect the
internal circuits from water penetration through the space between
the H7CX and operating panel, waterproof packing is included.
Attach the Y92F-30 Adapter with sufficient pressure with the
reinforcing screws so that water does not penetrate the panel.
screws alternately, a little at a time, so as to keep them at an equal
tightness. If the panel screws are tightened unequally, water may
enter the panel.
been stored at a temperature of less than
3 hours before use.
expectancies of internal components.
operating temperature and humidity.
• Locations subject to sudden or extreme changes in temperature.
• Locations where high humidity may result in condensation.
shock, water exposure, and oil exposure.
corrosive gasses are present, or in locations subject to direct
sunlight.
such as pipes transporting molding materials, powders, or liquids.
10 C, allow the Counter to stand at room temperature for at least
Precautions for Safe Use
0.5 to 1 mm
CAUTION
It is recommended that the
space between the screw
head and the Adapter be
0.5 to 1 mm.
• Internal elements may be destroyed if a voltage outside the rated
• Be sure that polarity is correct when wiring the terminals.
• Separate the Counter from sources of noise, such as devices with
• Do not connect more than two crimp terminals to the same
• Up to two wires of the same size and type can be inserted into a
• Use the specified wires for wiring. Applicable Wires: AWG 18 to
• Install a switch or circuit breaker that allows the operator to
• When the Counter is operated with no-voltage input (NPN input),
• Use a switch, relay, or other contact so that the rated power supply
• Use a switch, relay, or other contact to turn the power supply OFF
• When changing the set value during operation, because the H7CX
• When changing the comparison value during operation, because
• If the set value and present value are both 0, the output will turn
• When the power is turned ON using the factory settings, the output
• Do not use organic solvents (such as paint thinners or benzine),
• Confirm that indications are working normally, including the
• The waterproof packing may deteriorate, shrink, or harden
voltage range is applied.
input signals from power lines carrying noise, and wiring for I/O
signals.
terminal.
single terminals.
AWG 22, solid or twisted, copper
immediately turn OFF the power, and label it to clearly indicate its
function.
approximately 14 V is output from the input terminals. Use a sensor
that contains a diode.
voltage will be reached within 0.1 seconds. If the power supply
voltage is not reached quickly enough, the Counter may
malfunction or outputs may be unstable.
instantaneously. Outputs may malfunction and memory errors may
occur if the power supply voltage is decreased gradually.
uses a constant read-in system, output will turn ON if the set value
is equal to the present value.
the H7CX uses a constant read-in system, the output status will
change if the comparison value is changed to a value on the other
side of the present value.
ON for the default setting. The output will turn OFF during a reset
operation.
will turn ON after 999.9 s if no pulses are received as count input.
strong alkali, or strong acids. They will damage the external finish.
backlight LED, and LCD. The indicator LEDs, LCD, and resin parts
may deteriorate more quickly depending on the application
environment, preventing normal indications. Periodic inspection
and replacement are required.
depending on the application environment. Periodic inspection and
replacement are required.
0 V
Sensor
Input
Diode

Related parts for H7CX-A4-N AC100-240