Specifications of H7CX-A4-N AC100-240

Brand/series
H7CX
Connection Type
Screw Terminals
Contact Form
3 A at 250VAC/30 VDC
Dimensions
58H x 48W x 98.5D
Display Type
7 Segment LCD
Function
Multifunction Digital Counter
Input Type
Increment, Decrement, Command, Individual and Quadrature
Ip Rating
IP66
Mounting Type
Flush
Number Of Inputs
4
Number Of Outputs
1
Output Type
SPDT
Primary Type
Digital Counter
Voltage, Supply
100-240 VAC
*1. Not supported by the H7CX-A11@-N.
*2. The functions that can be selected depend on the model.
Specifications
Ratings
*1. 1-stage preset counter and total counter functionality.
*2. Do not use the output from an inverter as the power supply.The ripple must be 20% maximum for DC power.
*3. A response of 10 kHz is possible if the response speed is 5 kHz and the 1-stage preset counter input mode is increment, decrement, or increment/
*4. The display is lit only when the power is ON. Nothing is displayed when power is OFF.
• Easy to check the output status from a long distance with changing
• Includes total and preset counter, batch counter, dual counter, twin
Item
Classification
Configuration
Ratings
Mounting method
External connections
Degree of protection
Input signals
Counter
Tachometer
Prescaling function
Decimal point adjustment
Sensor waiting time
Input method
External power supply
Control output
Display*4
Digits
Memory backup
Operating temperature
range
Storage temperature range
Operating humidity range
Case color
Attachments
display colors
counter, and tachometer.
decrement (command input).
H7CX-A@-N Multifunction Preset Counter
Power supply
voltage*2
Operating volt-
age fluctuation
range
Power con-
sumption
Maximum
counting speed
Input mode
Output mode
One-shot out-
put time
Reset system
Models
*1
(red, green, and orange).
Preset counter
1-stage preset counter, 1-stage preset counter with total counter (selectable)*1
• 100 to 240 VAC, 50/60 Hz
• 24 VAC, 50/60 Hz or 12 to 24 VDC
85% to 110% of rated supply voltage (12 to 24 VDC: 90% to 110%)
Approx. 9.4 VA at 100 to 240 VAC, Approx. 7.2 VA/4.7 W at 24 VAC/12 to 24 VDC, Approx. 3.7 W at 12 to 24 VDC
Flush mounting or surface mounting
11-pin socket
IEC IP66, UL508 Type 4X (indoors) for panel surface only and only when Y92S-29 Waterproof Packing is used.
CP1, CP2, reset, and total reset
30 Hz or 5 kHz (switchable) (ON/OFF ratio 1:1)*3
*Common setting for CP1 and CP2
Increment, decrement, increment/decrement (UP/DOWN A (command input), UP/DOWN B (individual inputs), or UP/DOWN C (quadrature inputs))
N, F, C, R, K-1, P, Q, A, K-2, D, and L.
0.01 to 99.99 s
External (minimum reset signal width: 1 ms or 20 ms, selectable), manual, and automatic reset (internal according to C, R, P, and Q mode operation)
Refer to the separate table for tachometer function ratings.
Yes (0.001 to 9.999)
Yes (rightmost 3 digits)
290 ms max. (Control output is turned OFF and no input is accepted during sensor waiting time.)
No-voltage inputs:
ON impedance: 1 k
ON residual voltage: 3 V max.
OFF impedance: 100 k
Voltage input:
High (logic) level: 4.5 to 30 VDC
Low (logic) level: 0 to 2 VDC (Input resistance: approx. 4.7 k )
No-voltage input/voltage input (switchable)
12 VDC ( 10%), 100 mA (except for H7CX-A@D models) Refer to Precautions for Correct Use on page page 53 for details.
• Contact output: 3 A at 250 VAC/30 VDC, resistive load (cos =1), Minimum applied load: 10 mA at 5 VDC (failure level: P, reference value)
• Transistor output: NPN open collector, 100 mA at 30 VDC, Residual voltage: 1.5 VDC max. (approx. 1 V), Leakage current: 0.1 mA max.
7-segment, negative
transmissive LCD
Character height
Count value: 12 mm
(red)
Set value: 6 mm (green)
4 digits
( 3 digits to +4 digits)
EEPROM (overwrites: 100,000 times min.) that can store data for 10 years min.
25% to 85%
Black (N1.5) (Optional Front Panels are available to change the Front Panel color to light gray or white.)
999 to 9999
10 to 55 C ( 10 to 50 C if Counter/Tachometers are mounted side by side) (with no icing or condensation)
25 to 70 C (with no icing or condensation)
H7CX-A114@-N
*2
max. (Leakage current: 12 mA at 0 )
---
min.
Yes (0.001 to 99.999)
7-segment, negative
transmissive LCD
Character height
Count value: 10 mm
(red)
Set value: 6 mm (green)
6 digits
( 5 digits to +6 digits)
99999 to 999999
H7CX-A11@-N
• 100 to 240 VAC, 50/60 Hz
• 12 to 24 VDC
Flush mounting
Screw terminals
Yes (0.001 to 9.999)
7-segment, negative
transmissive LCD
Character height
Count value: 12 mm
(red, green, or orange
selectable)
Set value: 6 mm (green)
4 digits
( 3 digits to +4 digits)
Flush mounting adapter, waterproof packing, terminal cover
999 to 9999
H7CX-A4@-N
Yes (0.001 to 99.999)
7-segment, negative
transmissive LCD
Character height
Count value: 10 mm
(red, green, or orange
selectable)
Set value: 6 mm (green)
6 digits
( 5 digits to +6 digits)
99999 to 999999
H7CX-A@-N
1-stage/2-stage preset
counter, total and preset
counter*1, batch
counter, dual counter,
and twin counter
(selectable)
CP1, CP2, reset 1, and reset 2
N, F, C, R, K-1, P, Q, A, K-2, D, L, and H.
Yes (0.001 to 9.999)
7-segment, negative
transmissive LCD
Character height
Count value: 12 mm
(red, green, or orange
selectable)
Set value: 6 mm (green)
4 digits
( 3 digits to +4 digits)
999 to 9999
H7CX-A4W@-N
H7CX-A@-N
Preset counter/
tachometer
1-stage/2-stage preset
counter, total and preset
counter*1, batch
counter, dual counter,
twin counter, and
tachometer (selectable)
• 100 to 240 VAC at 50/
• 24 VAC at 50/60 Hz or
• 12 to 24 VDC
Yes (0.001 to 99.999)
7-segment, negative
transmissive LCD
Character height
Count value: 10 mm
(red, green, or orange
selectable)
Set value: 6 mm (green)
6 digits
( 5 digits to +6 digits),
tachometer: 0 to 999999
Flush mounting adapter,
waterproof packing,
terminal cover, label for
DIP switch settings
H7CX-AW@-N/-AU@-N
99999 to 999999
60 Hz
12 to 24 VDC
5