Page 1
FP Lineup V3, the 32-k-step type PLC, widens the applications! (No price changes, completely upward compatible) Control Units C32 Control unit (NPN Tr.) V3 FPG-C32TH Existing FPG-C32T model Positioning FPΣ Expansion Units ( units can be added.) ...
Page 2
C32 Control unit (NPN Tr.) C32 Control unit with thermistor input Left-side expansion type with linear and circular interpolation functions and thermistor input FPG-C32THTM FPG-C32T2HTM FPG-C32TTM FPG-C32T2TM FP0 Expansion Units Input/Output Units 8 points: Input 4/Relay output 4 Terminal block ...
Page 3
... Modbus master/slave RTU 7. MEWTOCOL Master 8. Tool port: Supports general-purpose serial communications. 9. 512 steps can be rewritten simultaneously in RUN mode. 10. Internal relays: 4,096 points Link relays: 2,048 points FPG-C32T2H/FPG-C32T2HTM FPG-C32T/FPG-C32TTM FPG-C32T2/FPG-C32T2TM 32 points 32 points (DC input: 16, NPN output: 16) Max. 128 points ( units) * When using transistor output type ...
Page 4
I General Specifications Item Rated operating voltage Operating voltage range 21 C32 Allowed momentary 21 26.4 V power off time C28 ...
Page 5
FP I High-speed counter, Pulse output and PWM output Specifications Item Input point number Maximum counting speed Input mode High-speed counter Input contact used (see note 1) Output point number Output mode Maximum output frequency Pulse output High-speed counter ...
Page 6
FP Positioning Unit 1-axis 1-axis transistor output line driver output FPG-PP11 FPG-PP12 I Performance Specifications Part number Output type Occupied I/O points Input: 16 points, Output: 16 points Number of axes controlled Command units Pulse unit (The program specifies ...
Page 7
FP /FP0 CC-Link Slave Unit Available for Open Network CC-Link Σ FP CC-Link Slave Unit FPG-CCLS I Specification 1. General Specifications Rated operating voltage Operating voltage range 21 CC-Link Unit ...
Page 8
FP S-LINK unit Comprises the S-LINK wire-saving system (SUNX Ltd.) and controls up to 128 I/O points at a transmission distance 400 four units can be connected. Each unit can control up ...
Page 9
FP Data Memory Expansion Unit Data capacity expandable up to 256 k words I General Specifications Item Ambient temperature 55° (No condensation) humidity Storage temperature/ -20 to +70° ...
Page 10
FP Dimensions and Restrictions when combining unit and using programming tools I FP Σ Control units FPG-C32TH/FPG-C32T2H/FPG-C28P2H V3 FPG-C32THTM/FPG-C32T2HTM/FPG-C28P2HTM FPG-C32T/FPG-C32T2/FPG-C28P2 FPG-C32TTM/FPG-C32T2TM/FPG-C28P2TM 30 Σ Expansion units/FP0 Expansion units FPG-XY64D2T 30.0 FPG-EM1 30.0 I Restrictions when combining unit and ...
Page 11
FP Product types 1 Control units Product name Σ Input 16 points DC, Transistor output (NPN) 16 points FP C32 I/O control points when expanded: Max. 128 points Control unit Σ Input 16 points DC, Transistor output (NPN) 16 ...
Page 12
Intelligent units for FP and FP0 Product name thermocouple, Resolution: 0.1°C FP0 Thermocouple unit thermocouple, Resolution: 0.1°C Unit for connecting FP series/RS232C interface and Ethernet FP Web-Server unit Web-Server function ...
Page 13
Please contact .......... ARCT1B208E-2 200512-1.2XT These materials are printed on ECF pulp. These materials are printed with earth-friendly vegetable-based (soybean oil) ink. Matsushita Electric Works, Ltd. Automation Controls Business Unit Head Office: 1048, Kadoma, Kadoma-shi, Osaka 571-8686, Japan All Rights ...