FPWINPRO6-SMALL Panasonic Electric Works, FPWINPRO6-SMALL Datasheet

no-image

FPWINPRO6-SMALL

Manufacturer Part Number
FPWINPRO6-SMALL
Description
Software, Version 6.0
Manufacturer
Panasonic Electric Works
Datasheet
FP
V3, the 32-k-step type PLC, widens the applications!
(No price changes, completely upward compatible)
8
Matsushita Electric Industrial Co.,
Ltd. MINAS Series
Expansion I/O unit
FPG-XY64D2T
Control Units
FP Σ Expansion Units
Communication Cassettes
RS232C type
FPG-COM1
1-channel
64 points
Positioning
Existing
model
Σ
V3
Lineup
transistor output
RS232C type
FPG-COM2
2-channel
FPG-PP11
1-axis
C32 Control unit
Positioning units
FPG-C32TH
FPG-C32T
Expansion Units
(Up to 4 units can
RS485 (isolated) type
line driver output
be added.)
FPΣ
FPG-PP12
FPG-COM3
1-channel
1-axis
(NPN Tr.)
Motor driver I/F terminal II
transistor output
C32 Control unit
Left-side expansion type
RS485 (isolated) type
FPG-PP21
with linear and circular
interpolation functions
2-axis
AFP8503
Positioning units
FPG-COM4
1-axis
FPG-C32T2H
1-channel
1-channel
RS232C/
FPG-C32T2
line driver output
(NPN Tr.)
FPG-PP22
2-axis
Control Unit
AFP8504
Communication
2-axis
C24 Control unit (Relay output)
FPΣ
Left-side expansion type
expansion unit
Data memory
with linear and circular
interpolation functions
FPG-EM1
RUN
PROG.
ERROR
ALARM
RUN
PROG.
COM.1
COM.2
FPG-C24R2H
S
R
S
R
FPG-C24R2
X0-7
Y0-7
max.
min.
X8-F
Y8-F
V0
V1
0
2
4
6
8
A
C
E
0
2
4
6
8
A
C
E
1
3
5
7
9
B
D
F
1
3
5
7
9
B
D
F
CC-Link slave unit
FPG-CCLS
Data clear type/Data hold type
FP Memory Loader
X0-7
Y0-7
X8-F
Y8-F
A
C
E
A
C
E
0
2
4
6
8
0
2
4
6
8
1
3
5
7
9
B
D
F
1
3
5
7
9
B
D
F
C28 Control unit
AFP8670/AFP8671
X0-7
Y0-7
Left-side expansion type
with linear and circular
interpolation functions
X8-F
Y8-F
A
C
E
A
C
E
0
2
4
6
8
0
2
4
6
8
1
3
5
7
9
B
D
F
1
3
5
7
9
B
D
F
X0-7
Y0-7
FPG-C28P2H
X8-F
Y8-F
FPG-C28P2
A
C
E
A
C
E
0
2
4
6
8
0
2
4
6
8
1
3
5
7
9
B
D
F
1
3
5
7
9
B
D
F
S-LINK unit
Expansion Units
(Up to 3 units can
FPG-SL
be added.)
(PNP Tr.)
FP0

Related parts for FPWINPRO6-SMALL

FPWINPRO6-SMALL Summary of contents

Page 1

FP Lineup V3, the 32-k-step type PLC, widens the applications! (No price changes, completely upward compatible) Control Units C32 Control unit (NPN Tr.) V3 FPG-C32TH Existing FPG-C32T model Positioning FPΣ Expansion Units ( units can be added.) ...

Page 2

C32 Control unit (NPN Tr.) C32 Control unit with thermistor input Left-side expansion type with linear and circular interpolation functions and thermistor input FPG-C32THTM FPG-C32T2HTM FPG-C32TTM FPG-C32T2TM FP0 Expansion Units Input/Output Units 8 points: Input 4/Relay output 4 Terminal block ...

Page 3

... Modbus master/slave RTU 7. MEWTOCOL Master 8. Tool port: Supports general-purpose serial communications. 9. 512 steps can be rewritten simultaneously in RUN mode. 10. Internal relays: 4,096 points Link relays: 2,048 points FPG-C32T2H/FPG-C32T2HTM FPG-C32T/FPG-C32TTM FPG-C32T2/FPG-C32T2TM 32 points 32 points (DC input: 16, NPN output: 16) Max. 128 points ( units) * When using transistor output type ...

Page 4

I General Specifications Item Rated operating voltage Operating voltage range 21 C32 Allowed momentary 21 26.4 V power off time C28 ...

Page 5

FP I High-speed counter, Pulse output and PWM output Specifications Item Input point number Maximum counting speed Input mode High-speed counter Input contact used (see note 1) Output point number Output mode Maximum output frequency Pulse output High-speed counter ...

Page 6

FP Positioning Unit 1-axis 1-axis transistor output line driver output FPG-PP11 FPG-PP12 I Performance Specifications Part number Output type Occupied I/O points Input: 16 points, Output: 16 points Number of axes controlled Command units Pulse unit (The program specifies ...

Page 7

FP /FP0 CC-Link Slave Unit Available for Open Network CC-Link Σ FP CC-Link Slave Unit FPG-CCLS I Specification 1. General Specifications Rated operating voltage Operating voltage range 21 CC-Link Unit ...

Page 8

FP S-LINK unit Comprises the S-LINK wire-saving system (SUNX Ltd.) and controls up to 128 I/O points at a transmission distance 400 four units can be connected. Each unit can control up ...

Page 9

FP Data Memory Expansion Unit Data capacity expandable up to 256 k words I General Specifications Item Ambient temperature 55° (No condensation) humidity Storage temperature/ -20 to +70° ...

Page 10

FP Dimensions and Restrictions when combining unit and using programming tools I FP Σ Control units FPG-C32TH/FPG-C32T2H/FPG-C28P2H V3 FPG-C32THTM/FPG-C32T2HTM/FPG-C28P2HTM FPG-C32T/FPG-C32T2/FPG-C28P2 FPG-C32TTM/FPG-C32T2TM/FPG-C28P2TM 30 Σ Expansion units/FP0 Expansion units FPG-XY64D2T 30.0 FPG-EM1 30.0 I Restrictions when combining unit and ...

Page 11

FP Product types 1 Control units Product name Σ Input 16 points DC, Transistor output (NPN) 16 points FP C32 I/O control points when expanded: Max. 128 points Control unit Σ Input 16 points DC, Transistor output (NPN) 16 ...

Page 12

Intelligent units for FP and FP0 Product name thermocouple, Resolution: 0.1°C FP0 Thermocouple unit thermocouple, Resolution: 0.1°C Unit for connecting FP series/RS232C interface and Ethernet FP Web-Server unit Web-Server function ...

Page 13

Please contact .......... ARCT1B208E-2 200512-1.2XT These materials are printed on ECF pulp. These materials are printed with earth-friendly vegetable-based (soybean oil) ink. Matsushita Electric Works, Ltd. Automation Controls Business Unit Head Office: 1048, Kadoma, Kadoma-shi, Osaka 571-8686, Japan All Rights ...

Related keywords