I General Specifications
I Output Specifications
1. Relay Output Specifications (C24)
Rated operating voltage
Operating voltage range
Allowed momentary
power off time
Ambient temperature
Storage temperature
Ambient humidity
Storage humidity
Breakdown voltage
Insulation resistance
Vibration
resistance
Shock resistance
Noise immunity
Operating condition
Output type
Rated control capacity
Output points per common
Response time
Lifetime
Surge absorber
Operating mode indicator
Item
Item
OFF→ON
ON→OFF
Mechanical
Electrical
C32
C28
C24
C32
C28
C24
C32
C28
C24
24 V DC
21.6 to 26.4 V DC
4 ms at 21.6 V, 7 ms at 24 V, 10 ms at 26.4 V
3 ms at 21.6 V, 5 ms at 24 V, 8 ms at 26.4 V
0 to +55°C
–20 to +70°C
30 to 85 % RH (at 25°C, non-condensing)
30 to 85 % RH (at 25°C, non-condensing)
Between input/output terminals and
power supply terminal/function earth
Between input terminal and output
terminal
Between input terminals (X0 to X7)/input
terminals (X8 to XF) and power supply
terminal/function earth
Between output terminals and power
supply terminal/function earth
Between input terminals (X0 to X7) and
input terminals (X8 to XF)
Between input terminals (X0 to X7)/input
terminals (X8 to XF) and output terminals
Between input/output terminals and
power supply terminal/function earth
Between input terminal and output
terminal
Between input terminals (X0 to X7)/input
terminals (X8 to XF) and power supply
terminal/function earth
Between output terminals and power
supply terminal/function earth
Between input terminals (X0 to X7) and
input terminals (X8 to XF)
Between input terminals (X0 to X7)/input
terminals (X8 to XF) and output terminals
10 to 55 Hz, 1 cycle/min: double amplitude of
0.75 mm/0.030 in., 10 min on 3 axes
Shock of 98 m/s
1,000 Vp-p with pulse widths 50 ns and 1 µs
(based on in-house measurements)
Free from corrosive gases and excessive dust
1a (1 Form A, Normally open)
2 A 250 V AC, 2 A 30 V DC
(4.5 A or less per common)
8 points/common
Approx. 10 ms
Approx. 8 ms
Min. 20,000,000 operations
Min. 100,000 operations
LED display
32 to +131 °F
–4 to +158 °F
2
or more, 4 times on 3 axes
Description
Description
500 VAC
for 1 minute
500 VAC
for 1 minute
1,500 VAC
for 1 minute
500 VAC
for 1 minute
1,500 VAC
for 1 minute
Min. 100 MΩ
(measured
with a
500 V DC
megger)
2. Transistor Output Specifications (C32 and C28)
Insulation method
Output type
Rated load voltage
Operating load voltage range
Max. load current
Max. surge current
Output points per common
OFF state leakage current
ON state voltage drop
Response time
External power supply
for driving internal
circuit
Response time
Operating mode indicator
Phase fault protection
I Input Specifications
Note: X0 through X7 are inputs for the high-speed counter and have a fast
Insulation method
Rated input voltage
Operating voltage range
Rated input current
Input points per common
Min. ON voltage/
Min. ON current
Max. OFF voltage/
Max. OFF current
Input impedance
Response
time
Operating mode indicator
Programmable Controllers
Item
response time.
If used as normal inputs, we recommend inserting a timer in the ladder
program as chattering and noise may be interpreted as an input signal.
The above specifications apply when the rated input voltage is 24 VDC and
the temperature is 25°C 70°F.
OFF→ON
ON→OFF
Voltage
Current
Item
OFF→ON
ON→OFF
Optical coupler
Open collector (NPN)
5 to 24 V DC
4.75 to 26.4 V DC
For Y0, Y1, Y3, Y4: 0.3 A
For Y2, Y5 to YF: 0.1 A
For Y0, Y1, Y3, Y4: 0.9 A
For Y2, Y5 to YF: 0.5 A
16 points/common
100 µA or less
0.5 V or less
For Y0, Y1, Y3, Y4 (When the load current is
15 mA or more.): 2 µs or less
For Y2, Y5 to YF: 0.2 ms or less
For Y0, Y1, Y3, Y4 (When the load current is
15 mA or more.): 8 µs or less
For Y2, Y5 to YF: 0.5 ms or less
21.6 to 26.4 V DC
70 mA or less
Zener diode
LED display
Thermal protection for Y2, Y5 to YF
Optical coupler
24 V DC
21.6 to 26.4 V DC
For X0, X1, X3, X4: approx. 8 mA
For X2, X5 to X7: approx. 4.3 mA
For X8 to XF: approx. 3.5 mA
C32, C28: 16 points/common
C24: 8 points/common
(Either the positive or negative of the
input power supply can be connected to
the common terminal.)
For X0, X1, X3, X4: 19.2 V DC/6 mA
For X2, X5 to XF: 19.2 V DC/3 mA
2.4 V DC/1.3 mA
For X0, X1, X3, X4: 3 kΩ
For X2, X5 to X7: 5.6 kΩ
For X8 to XF: 6.8 kΩ
For input X0, X1, X3, X4:
For input X2, X5 to X7:
For input X8 to XF:
Same as above
LED display
C32 (NPN)
1 ms or less: normal input
5 µs or less: high-speed counter,
1 ms or less: normal input
100 µs or less: high-speed counter,
1 ms or less: normal input only
Description
Description
pulse catch, interrupt
input settings
pulse catch, interrupt
input settings
Open collector (PNP)
24 V DC
21.6 to 26.4 V DC
For Y0, Y1, Y3, Y4: 0.5 A
For Y2, Y5 to YF: 0.3 A
For Y0, Y1, Y3, Y4: 1.5 A
For Y2, Y5 to YF: 0.7 A
12 points/common
C28 (PNP)
SIGMA
11