RTE-P2D12 IDEC Corporation, RTE-P2D12 Datasheet - Page 3

no-image

RTE-P2D12

Manufacturer Part Number
RTE-P2D12
Description
Relay; SSR; Timing; Multi-Function; DPDT; Cur-Rtg 10A; Ctrl-V 12DC; Vol-Rtg 240/30AC/DC
Manufacturer
IDEC Corporation
Datasheet

Specifications of RTE-P2D12

Brand/series
RTE Series
Contact Form
DPDT
Current, Rating
10 A
Function
Timing
Mounting Type
PCB
Number Of Pins
11
Relay Type
Solid State
Standards
cULus, CE, TUV
Temperature, Operating, Maximum
65 °C
Temperature, Operating, Minimum
-20 °C
Termination
Solder
Timer Type
Multi-Function
Timing Range
0.1 sec. to 600 hrs.
Voltage, Control
12 VDC
Voltage, Rating
240⁄30 VAC⁄VDC
Multifunction Operation
On-Delay/Interval or Off-Delay/Single-Shot
Lead Free Status / Rohs Status
RoHS Compliant part
800
A: ON-Delay 1 (power start)
Set timer for desired delay, apply power to coil. Contacts transfer after preset time has elapsed, and
remain in transferred position until timer is reset. Reset occurs with removal of power.
C: Cycle 1 (power start, OFF fi rst)
Set timer for desired delay, apply power to coil. First transfer of contacts occurs after preset delay has
elapsed, after the next elapse of preset delay contacts return to original position. The timer now cycles
between on and off as long as power is applied (duty ratio 1:1).
Power
Delayed
Contact
Indicator
Set Time
Power
Delayed
Contact
Indicator
Set Time
Item
Item
(1) 2 - 7
(2) A - B
(1) 1 - 4, 5 - 8
(2) 1 - 7, 3 - 9
(1) 1 - 3, 6 - 8
(2) 4 - 7, 6 - 9
PWR
OUT
(1) 2 - 7
(2) A - B
(1) 1 - 4, 5 - 8
(2) 1 - 7, 3 - 9
(1) 1 - 3, 6 - 8
(2) 4 - 7, 6 - 9
PWR
OUT
Terminal Number
Terminal Number
(~/+)
(NC)
(NO)
(NC)
(NO)
3
2
RTE-P1
4
1
RTE Series
5
8
6
7
(~/-)
T
T
T
(~/+)
1
4
A
RTE-B1
7
Operation
Operation
2
5
8
3
6
9
B
(~/-)
Timing Diagrams
www.idec.com
RTE-P1, -B1
B: Interval (power start)
Set timer for desired delay, apply power to coil. Contacts transfer immediately, and return to original
position after preset time has elapsed. Reset occurs with removal of power.
C: Cycle 3 (power start, ON fi rst)
Functions in same manner as Mode C, with the exception that fi rst transfer of contacts occurs as soon
as power is applies. The ratio is 1:1. Time On = Time Off
1. RTE-B1: Do not apply voltage to terminals #2, #5 & #8.
2. IDEC sockets are as follows: RTE-P1: SR2P-06* pin type socket,
Power
Delayed
Contact
Indicator
Set Time
Power
Delayed
Contact
Indicator
Set Time
Item
Item
RTE-B1: SR3B-05* blade type socket, (*-may be followed by suffi x
letter A,B,C or U).
(1) 2 - 7
(2) A - B
(1) 1 - 4, 5 - 8
(2) 1 - 7, 3 - 9
(1) 1 - 3, 6 - 8
(2) 4 - 7, 6 - 9
PWR
OUT
(1) 2 - 7
(2) A - B
(1) 1 - 4, 5 - 8
(2) 1 - 7, 3 - 9
(1) 1 - 3, 6 - 8
(2) 4 - 7, 6 - 9
PWR
OUT
Terminal Number
Terminal Number
(NC)
(NO)
(NC)
(NO)
T
T
T
Operation
Operation
Timers

Related parts for RTE-P2D12