RTE-P2D12 IDEC Corporation, RTE-P2D12 Datasheet - Page 4

no-image

RTE-P2D12

Manufacturer Part Number
RTE-P2D12
Description
Relay; SSR; Timing; Multi-Function; DPDT; Cur-Rtg 10A; Ctrl-V 12DC; Vol-Rtg 240/30AC/DC
Manufacturer
IDEC Corporation
Datasheet

Specifications of RTE-P2D12

Brand/series
RTE Series
Contact Form
DPDT
Current, Rating
10 A
Function
Timing
Mounting Type
PCB
Number Of Pins
11
Relay Type
Solid State
Standards
cULus, CE, TUV
Temperature, Operating, Maximum
65 °C
Temperature, Operating, Minimum
-20 °C
Termination
Solder
Timer Type
Multi-Function
Timing Range
0.1 sec. to 600 hrs.
Voltage, Control
12 VDC
Voltage, Rating
240⁄30 VAC⁄VDC
Multifunction Operation
On-Delay/Interval or Off-Delay/Single-Shot
Lead Free Status / Rohs Status
RoHS Compliant part
Timers
A: ON-Delay 2 (signal start)
When a preset time has elapsed after the start input turned on while power is on, the NO output
contact goes on.
C: Cycle 4 (signal start, ON fi rst)
When the start input turns on while power is on, the NO contact goes on. The output oscillates at a
preset cycle (duty ratio 1:1).
E: Signal OFF-Delay
When power is turned on while the start input is on, the NO output contact goes on. When a preset
time has elapsed after the start input turned off, the NO output contact goes off.
Power
Start
Delayed
Contact
Indicator
Set Time
Power
Start
Delayed
Contact
Indicator
Set Time
Power
Start
Delayed
Contact
Indicator
Set Time
Item
Item
Item
(A) 2 - 10
(B) A - B
(A) 5 - 6
(B) 2 - 5
(A) 1 - 4, 8 - 11
(B) 1 - 7, 3 - 9
(A) 1 - 3, 9 - 11
(B) 4 - 7, 6 - 9
PWR
OUT
(A) 2 - 10
(B) A - B
(A) 5 - 6
(B) 2 - 5
(A) 1 - 4, 8 - 11
(B) 1 - 7, 3 - 9
(A) 1 - 3, 9 - 11
(B) 4 - 7, 6 - 9
PWR
OUT
(A) 2 - 10
(B) A - B
(A) 5 - 6
(B) 2 - 5
(A) 1 - 4, 8 - 11
(B) 1 - 7, 3 - 9
(A) 1 - 3, 9 - 11
(B) 4 - 7, 6 - 9
PWR
OUT
Terminal Number
Terminal Number
Terminal Number
external
control
signal
(~/+)
(NC)
(NO)
(NC)
(NO)
(NC)
(NO)
RTE-P2
3
4
2
5 6
start
1
11
7
10
8
9
(~/-)
T
T
T
external
control
signal
(~/+)
T
T
1
4
A
RTE-B2
7
Operation
Operation
Operation
T
start
Ta
2
5
8
USA: 800-262-IDEC
T
3
6
9
B
(~/-)
T
T
T
Timing Diagrams con’t
T
Ta
Ta
RTE-P2, -B2
Canada: 888-317-IDEC
B: Cycle 2 (signal start, OFF fi rst)
When the start input turns on while power is on, the output oscillates at a preset cycle (duty ratio 1:1),
starting while the NO contact off.
D: Signal ON/OFF-Delay
When the start input turns on while power is on, the NO output contact goes on. When a preset time
has elapsed while the start input remains on, the output contact goes off. When the start input turns
off, the NO contact goes on again. When a preset time has elapsed after the start input turned off, the
NO contact goes off.
F: One-Shot (signal start)
When the start input turns on while power is on, the NO output contact goes on. When a preset time
has elapsed, the NO output contact goes off.
Power
Start
Delayed
Contact
Indicator
Set Time
Power
Start
Delayed
Contact
Indicator
Set Time
Power
Start
Delayed
Contact
Indicator
Set Time
1. RTE-P2: Do not apply voltage to terminals #5, #6 & #7.
2. RTE-B2: Do not apply voltage to terminals #2, #5 & #8.
3. IDEC sockets are as follows: RTE-P2: SR3P-05* pin type socket,
Item
Item
Item
RTE-B2: SR3B-05* blade type socket, (*-may be followed by suffi x
letter A,B,C or U).
(A) 2 - 10
(B) A - B
(A) 5 - 6
(B) 2 - 5
(A) 1 - 4, 8 - 11
(B) 1 - 7, 3 - 9
(A) 1 - 3, 9 - 11
(B) 4 - 7, 6 - 9
PWR
OUT
(A) 2 - 10
(B) A - B
(A) 5 - 6
(B) 2 - 5
(A) 1 - 4, 8 - 11
(B) 1 - 7, 3 - 9
(A) 1 - 3, 9 - 11
(B) 4 - 7, 6 - 9
PWR
OUT
(A) 2 - 10
(B) A - B
(A) 5 - 6
(B) 2 - 5
(A) 1 - 4, 8 - 11
(B) 1 - 7, 3 - 9
(A) 1 - 3, 9 - 11
(B) 4 - 7, 6 - 9
PWR
OUT
Terminal Number
Terminal Number
Terminal Number
(NC)
(NO)
(NC)
(NO)
(NC)
(NO)
T
T
T
T
T
RTE Series
T
Operation
Operation
Operation
T
Ta
T
T
T
T
T
T
Ta
Ta
801