H7CX-AD-N DC12-24 Omron Automation, H7CX-AD-N DC12-24 Datasheet - Page 22

no-image

H7CX-AD-N DC12-24

Manufacturer Part Number
H7CX-AD-N DC12-24
Description
Counter, Screw Terminal, SPDT Out, 6 Digits, Programmable Color Display
Manufacturer
Omron Automation
Type
Counterr
Datasheet

Specifications of H7CX-AD-N DC12-24

Brand/series
H7CX
Connection Type
Screw Terminals
Contact Form
3 A at 250VAC/30 VDC
Dimensions
58H x 48W x 98.5D
Display Type
7 Segment LCD
Function
Multifunction Digital Counter
Input Type
Increment, Decrement, Command, Individual and Quadrature
Ip Rating
IP66
Mounting Type
Flush
Number Of Inputs
4
Number Of Outputs
1
Output Type
SPDT
Primary Type
Digital Counter
Voltage, Supply
12-24 VDC
22
H7CX-A@-N
Counter
Input/Output Mode Settings
I/O Functions for Counter Operation
If a 1-stage model or 2-stage model is incorrectly used as twin counter, the operation for
output 2 will be performed. When using a 2-stage model as a 1-stage preset counter,
total and preset counter, or dual counter, OUT1 and OUT2 turn ON and OFF
simultaneously.
Output
mode
setting
K-1
N
C
R
F
Set value 2
Set value 1
Set value 2
Set value 1
Set value 2
Set value 1
Set value 2
Set value 1
Set value 2
Set value 1
999999
999999
999999
999999
reset 1
reset 1
999999
reset 1
reset 1
reset 1
Reset/
OUT1
OUT2
Reset/
OUT1
OUT2
Reset/
OUT1
OUT2
Reset/
OUT1
OUT2
Reset/
OUT1
OUT2
0
0
0
0
0
UP
Input mode
DOWN
Self-holding
output
UP/DOWN A, B, C
One-shot output from OUT1
Self-holding
output
output from OUT2
One-shot
(The one-shot output time can be
set in the range 0.01 to 99.99s.)
The outputs and present
value display are held
until reset/reset 1 is
input.
The present value
display continues to
increase/decrease.
The outputs are held until
reset/reset 1 is input.
As soon as the count
reaches SV, the present
value display returns to
the reset start status.
The present value display
does not show the
present value upon count-
up.
The outputs repeat one-
shot operation.
OUT1 self-holding output
turns OFF after the OUT2
one-shot output time.
The OUT1 one-shot
output time is
independent of OUT2.
The present value
display returns to the
reset start status after
the one-shot output time.
The outputs repeat one-
shot operation.
OUT1 self-holding output
turns OFF after the
OUT2 one-shot output
time.
The OUT1 one-shot
output time is
independent of OUT2.
The present value
display continues to
increase/decrease.
OUT1 self-holding output
turns OFF after the
OUT2 one-shot output
time.
The OUT1 one-shot
output time is
independent of OUT2.
Operation after count
completion

Related parts for H7CX-AD-N DC12-24