H7CX-AD-N DC12-24 Omron Automation, H7CX-AD-N DC12-24 Datasheet - Page 27

no-image

H7CX-AD-N DC12-24

Manufacturer Part Number
H7CX-AD-N DC12-24
Description
Counter, Screw Terminal, SPDT Out, 6 Digits, Programmable Color Display
Manufacturer
Omron Automation
Type
Counterr
Datasheet

Specifications of H7CX-AD-N DC12-24

Brand/series
H7CX
Connection Type
Screw Terminals
Contact Form
3 A at 250VAC/30 VDC
Dimensions
58H x 48W x 98.5D
Display Type
7 Segment LCD
Function
Multifunction Digital Counter
Input Type
Increment, Decrement, Command, Individual and Quadrature
Ip Rating
IP66
Mounting Type
Flush
Number Of Inputs
4
Number Of Outputs
1
Output Type
SPDT
Primary Type
Digital Counter
Voltage, Supply
12-24 VDC
Setting Procedure Guide
Tachometer Operation
After making DIP switch settings for basic operations, advanced functions can be added using the operation keys.
For details, refer to page page 28.
Note: All pins are factory-set to OFF.
Step1
Step2
When setting functions using the DIP switch, be sure to set pin 1 of the DIP switch to ON.
DIP switch settings are effective when the power is turned ON again. (Perform DIP switch settings while the power is OFF.)
1
2
3
4
5
6
7
8
Run mode
Power ON
Average processing
Tachometer output mode
DIP switch settings
Counting speed
Input selection
Set the basic parameters.
(If the desired I/O mode is not listed below or to set all parameters using the front panel keys, perform
below.)
The H7CX is factory-set to the 2-stage counter configuration (1-stage counter configuration for
H7CX-AU@-N models).
Enter configuration selection mode using the following chart and set the tachometer mode.
Note:
Item
---
Step2
Hold down for 1 s min.
Hold down for 1 s min.
Key-protect switch
can be performed first, followed by
+
+
1
1
Refer to the table on the right.
Refer to the table on the right.
Disabled
selection mode
30 Hz
Configuration
OFF
NPN
---
Enabled
10 kHz
PNP
ON
---
Switch from 2cnt (2-stage preset counter mode) to taco (tachometer mode)
using the U Key.
OFF
ON
Step1
1 2 3 4 5 6 7 8
.
Be sure to set pin 1 to ON.
Pin 3
Pin 5
OFF
OFF
OFF
OFF
ON
ON
ON
ON
Pin 4
Pin 6
OFF
OFF
OFF
OFF
ON
ON
ON
ON
Tachometer output mode
Upper/lower limit output
Average processing
Upper limit output
Lower limit output
H7CX-A@-N
Range output
Tachometer
2 times
4 times
8 times
OFF
Step3
,
27

Related parts for H7CX-AD-N DC12-24