H7CX-AD-N DC12-24 Omron Automation, H7CX-AD-N DC12-24 Datasheet - Page 24

no-image

H7CX-AD-N DC12-24

Manufacturer Part Number
H7CX-AD-N DC12-24
Description
Counter, Screw Terminal, SPDT Out, 6 Digits, Programmable Color Display
Manufacturer
Omron Automation
Type
Counterr
Datasheet

Specifications of H7CX-AD-N DC12-24

Brand/series
H7CX
Connection Type
Screw Terminals
Contact Form
3 A at 250VAC/30 VDC
Dimensions
58H x 48W x 98.5D
Display Type
7 Segment LCD
Function
Multifunction Digital Counter
Input Type
Increment, Decrement, Command, Individual and Quadrature
Ip Rating
IP66
Mounting Type
Flush
Number Of Inputs
4
Number Of Outputs
1
Output Type
SPDT
Primary Type
Digital Counter
Voltage, Supply
12-24 VDC
24
H7CX-A@-N
Counter
Note: 1. Counting cannot be performed during reset/reset 1 input.
Output
mode
setting
2. If reset/reset 1 is input while one-shot output is ON, one-shot output turns OFF.
3. If there is power failure while output is ON, output will turn ON again when the power supply has recovered.
4. Do not use the counter function in applications where the count may be completed (again) while one-shot output is ON.
5. The set value is from 99999 to 999999.
For one-shot output, output will turn ON again for the duration of the output time setting once the power supply has recovered.
K-2
D
H
L
Set value 2
Set value 1
Set value 2
Set value 1
Set value 2
Set value 1
Set value 2
Set value 1
999999
999999
reset 1
reset 1
Reset/
Reset/
99999
99999
999999
999999
OUT1
OUT2
OUT1
OUT2
reset 1
reset 1
Reset/
Reset/
99999
99999
OUT1
OUT2
OUT1
OUT2
0
0
0
0
UP/DOWN A, B, C
Input mode
Self-holding
output
Instantaneous
(equals) output
The display continues to increase/
decrease until the overflow or
underflow value is reached.
One-shot output only.
The display continues to increase/
decrease until the overflow or
underflow value is reached.
The outputs are ON while the count is
equal.
The display continues to increase/
decrease until the overflow or
underflow value is reached.
OUT1 is held while the present value
is less than or equal to set value 1.
OUT2 is held while the present value
is greater than or equal to set value 2.
The display continues to increase/
decrease until the overflow or
underflow value is reached.
OUT1 is held while the present value
is greater than or equal to set value 1.
OUT2 is held while the present value
is greater than or equal to set value 2.
* H mode is available only when using a 6-
Operation after count completion
digit model as a 2-stage counter.
One-shot
output
(The one-shot output time can be
set in the range 0.01 to 99.99s.)