LMV324MTX National Semiconductor, LMV324MTX Datasheet - Page 17

no-image

LMV324MTX

Manufacturer Part Number
LMV324MTX
Description
IC,Operational Amplifier,QUAD,BICMOS,TSSOP,14PIN,PLASTIC
Manufacturer
National Semiconductor
Datasheets

Specifications of LMV324MTX

Rohs Compliant
No

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
LMV324MTX
Manufacturer:
NS
Quantity:
1 000
Part Number:
LMV324MTX
Manufacturer:
NS/国半
Quantity:
20 000
Company:
Part Number:
LMV324MTX
Quantity:
1 275
Part Number:
LMV324MTX/NOPB
Manufacturer:
TI
Quantity:
5 600
Part Number:
LMV324MTX/NOPB
Manufacturer:
TI/NSC
Quantity:
65 000
Part Number:
LMV324MTX/NOPB
0
Application Notes
For minimum dc offset, V
inverting and non-inverting inputs should be equal, which
means
From Equation (1) and Equation (8), we obtain
The values of C
As a design example:
Require: A
Start by selecting C
is close to
From Equations (6), (7), (9), (10),
The above resistor values are normalized values with ω
1rad/s and C
frequency and resistances to the real values, two scaling
factors are introduced, frequency scaling factor (k
pedance scaling factor (k
Scaled values:
LP
1
= 2, Q = 1, fc = 1KHz
= C
1
2
and C
= C
1
R
R
C
and C
2
3
1
n
= R
= R
= C
2
= 1F. To scale the normalized cut-off
m
+
are normally close to or equal to
R
R
R
R
).
= V
1
4
2
1
2
3
4
2
. Choose a standard value that
= 1Ω
= 1Ω
= 4Ω
= 4Ω
= 15.9 kΩ
= 63.6 kΩ
= 0.01 µF
, the resistor values at both
(Continued)
f
) and im-
(10)
n
(8)
(9)
=
17
An adjustment to the scaling may be made in order to have
realistic values for resistors and capacitors. The actual value
used for each component is shown in the circuit.
4.4.3 2nd-order High Pass Filter
A 2nd-order high pass filter can be built by simply inter-
changing those frequency selective components (R
C
shown in Figure 14, resistors become capacitors, and ca-
pacitors become resistors. The resulted high pass filter has
the same corner frequency and the same maximum gain as
the previous 2nd-order low pass filter if the same compo-
nents are chosen.
4.4.4 State Variable Filter
A state variable filter requires three op amps. One conve-
nient way to build state variable filters is with a quad op amp,
such as the LMV324 (Figure 15).
This circuit can simultaneously represent a low-pass filter,
high-pass filter, and bandpass filter at three different outputs.
The equations for these functions are listed below. It is also
called "Bi-Quad" active filter as it can produce a transfer
function which is quadratic in both numerator and
denominator.
1
FIGURE 14. Sallen-Key 2nd-Order Active High-Pass
, C
2
) in the Sallen-Key 2nd-order active low pass filter. As
Filter
www.national.com
10006083
1
, R
2
,

Related parts for LMV324MTX