DS1878T+T&R Maxim Integrated Products, DS1878T+T&R Datasheet - Page 94

no-image

DS1878T+T&R

Manufacturer Part Number
DS1878T+T&R
Description
IC CTLR SFP W/DGTL LDD RX 28TQFN
Manufacturer
Maxim Integrated Products
Type
SFP+ Controllerr
Datasheet

Specifications of DS1878T+T&R

Input Type
*
Output Type
*
Interface
*
Current - Supply
*
Mounting Type
Surface Mount
Package / Case
28-WFQFN exposed Pad
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
SFP+ Controller with Digital LDD Interface
Table 06h, Register 80h–A3h: APC LUT
Table 06h, Register A4h–A7h: RESERVED
94
______________________________________________________________________________________
80h–A3h
FACTORY DEFAULT
READ ACCESS
WRITE ACCESS
MEMORY TYPE
These registers are reserved.
FACTORY DEFAULT
READ ACCESS
WRITE ACCESS
MEMORY TYPE
The APC LUT is a set of registers assigned to hold the temperature profile for the APC reference DAC. The
values in this table combined with the APC bits in the COMP RANGING register (Table 02h, Register B9h)
determine the set point for the APC loop. The temperature measurement is used to index the LUT (TINDEX, Table
02h, Register 81h) in 4°C increments from -40°C to +100°C, starting at Register 80h. Register 80h defines the
-40°C to -36°C APC reference value, Register 81h defines the -36°C to -32°C APC reference value, and so on.
Values recalled from this EEPROM memory table are written into the APC DAC (Table 02h, Register CDh)
location that holds the value until the next temperature conversion. The device can be placed into a manual
mode (APC EN bit, Table 02h, Register 80h), where the APC DAC can be directly controlled for calibration. If TE
temperature compensation is not required by the application, program the entire LUT to the desired APC set
point.
BIT 7
2
7
2
6
00h
PW2 or (PW1 and RWTBL246) or (PW1 and RTBL246)
PW2 or (PW1 and RWTBL246)
Nonvolatile (EE)
00h
N/A
N/A
Nonvolatile (EE)
2
5
2
4
2
3
Table 06h Register Descriptions
2
2
2
1
BIT 0
2
0

Related parts for DS1878T+T&R