AD8174ARZ Analog Devices Inc, AD8174ARZ Datasheet - Page 11

IC MUX SWITCHNG W/AMP 4:1 14SOIC

AD8174ARZ

Manufacturer Part Number
AD8174ARZ
Description
IC MUX SWITCHNG W/AMP 4:1 14SOIC
Manufacturer
Analog Devices Inc
Datasheet

Specifications of AD8174ARZ

Applications
Multiplexer with Amplifier
Voltage - Supply
±4 V ~ 6 V
Package / Case
14-SOIC (3.9mm Width), 14-SOL
Mounting Type
Surface Mount
No. Of Circuits
4
Supply Current
9.7mA
Supply Voltage Range
± 4V To ± 6V
Operating Temperature Range
-40°C To +85°C
Analog Switch Case Style
SOIC
No. Of Pins
14
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Interface
-
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
AD8174ARZ
Manufacturer:
ADI/亚德诺
Quantity:
20 000
Color Document Scanner
Charge Coupled Devices (CCDs) find widespread use in
scanner applications. A monochrome CCD delivers a serial
stream of voltage levels, each level being proportional to the
light shining on that cell. In the case of the color image scanner
shown, there are three output streams, representing red, green
and blue. Interlaced with the stream of voltage levels is a voltage
representing the reset level (or black level) of each cell. A
Correlated Double Sampler (CDS) subtracts these two voltages
from each other in order to eliminate the relatively large offsets
which are common with CCDs.
The next step in the data acquisition process involves digitizing
the three signal streams. Assuming that the analog to digital
converter chosen has a fast enough sample rate, multiplexing the
three streams into a single ADC is generally more economic
than using one ADC per channel. In the example shown, the
AD8174 is used to multiplex the red, green and blue channels
into the AD876, an 8- or 10-bit 20 MSPS ADC. Because of its
high bandwidth, the AD8174 is capable of driving the switched
capacitor input stage of the AD876 without additional buffering.
In addition to the bandwidth, it is necessary to consider the
settling time of the multiplexer. In this case, the ADC has a
sample rate of 20 MHz which corresponds to a sampling
period of 50 ns. Typically, one phase of the sampling clock is
used for conversion (i.e., all levels are held steady) and the other
REV. 0
IN0
IN1
IN2
IN3
IN4
IN5
IN6
IN7
75
75
75
75
75
75
75
75
–5V
–5V
0.1µF
0.1µF
10µF
+
10µF
+
1
4
1
2
5
2
3
5
6
7
3
4
6
7
GND
GND
–V
GND
GND
–V
+1
+1
+1
+1
+1
+1
+1
+1
S
S
Figure 26. 8-to-1 Multiplexer
2
2
AD8174
AD8174
2
2
+V
+V
–11–
S
S
14
13
12
10
14
13
12
10
11
11
9
8
9
8
phase is used for switching and settling to the next channel.
Assuming a 50% duty cycle, the signal chain must settle within
25 ns. With a settling time to 0.1% of 15 ns, the multiplexer
easily satisfies this criterion.
In the example shown, the fourth (spare) channel of the
AD8174 is used to measure a reference voltage. This voltage
would probably be measured less frequently than the R, G and
B signals. Multiplexing a reference voltage offers the advantage
that any temperature drift effects caused by the multiplexer will
equally impact the reference voltage and the to-be-measured
signals. If the fourth channel is unused, it is good design
practice to tie the input permanently to ground.
SD
ENABLE
SD
ENABLE
A1
A1
A0
A0
CCD
549
549
+5V
+5V
0.1µF
0.1µF
R
G
B
549
549
Figure 27. Color Document Scanner
REFERENCE
+
+
10µF
10µF
+5V
+5V
CDS
CDS
CDS
CONTROL AND TIMING
*
OPTIONAL
IN0
IN1
IN2
IN3
A0 A1 SD ENABLE
AD8174
AD8170/AD8174
R
75
BT
V
–V
OUT
IN
R
R
R
T
T
T
*
*
*
1k
(G = +1)
V
A2
A1
A0
OUT
20MSPS
8/10-BIT
AD876
A/D

Related parts for AD8174ARZ