LMH0034MA/NOPB National Semiconductor, LMH0034MA/NOPB Datasheet - Page 5

IC HD/SD ADAPTIVE CBL EQUALIZER

LMH0034MA/NOPB

Manufacturer Part Number
LMH0034MA/NOPB
Description
IC HD/SD ADAPTIVE CBL EQUALIZER
Manufacturer
National Semiconductor
Datasheets

Specifications of LMH0034MA/NOPB

Applications
*
Interface
*
Voltage - Supply
*
Package / Case
16-SOIC (3.9mm Width)
Mounting Type
Surface Mount
Operating Temperature (min)
0C
Operating Temperature Classification
Commercial
Operating Temperature (max)
85C
Package Type
SOIC N
Rad Hardened
No
For Use With
SD034EVK - BOARD EVALUATION LMH0034
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
*CLC034MA
*LMH0034MA
*LMH0034MA/NOPB
*LMH034MA
CLC034MA
CLC034MA
LMH0034MA
Block Diagram
Device Operation
BLOCK DESCRIPTION
The Equalizer Filter block is a multi-stage adaptive filter. If
Bypass is high, the equalizer filter is disabled.
The DC Restoration / Level Control block receives the dif-
ferential signals from the equalizer filter block. This block
incorporates a self-biasing DC restoration circuit to fully DC
restore the signals. If Bypass is high, this function is disabled.
The signals before and after the DC Restoration / Level Con-
trol block are used to generate the Automatic Equalization
Control (AEC) signal. This control signal sets the gain and
bandwidth of the equalizer filter. The loop response in the
AEC block is controlled by an external 1µF capacitor placed
across the AEC+ and AEC- pins. Cable Length Indicator
(CLI) is derived from this block.
The Carrier Detect / Mute block generates the carrier detect
signal and controls the mute function of the output. This block
utilizes the bi-directional CD/MUTE signal along with Mute
Reference (MUTE
The Output Driver produces SDO and SDO.
CABLE LENGTH INDICATOR (CLI)
The cable length indicator provides a voltage to indicate the
length of cable being equalized. The CLI voltage decreases
as the cable length increases.
voltage vs. Belden 1694A cable length. Note: CLI is only valid
when an input signal is present.
REF
).
Figure 1
shows the typical CLI
5
MUTE REFERENCE (MUTE
The mute reference determines the amount of cable to equal-
ize before automatically muting the outputs. This is set by
applying a voltage inversely proportional to the length of cable
to equalize. As the applied MUTE
amount of cable that can be equalized before carrier detect is
de-asserted and the outputs are muted is decreased.
MUTE
before muting.
FIGURE 1. CLI vs. Belden 1694A Cable Length
REF
may be left unconnected for maximum equalization
2.6
2.5
2.4
2.3
2.2
2.1
2.0
1.9
1.8
0
BELDEN 1694A CABLE LENGTH (m)
50 100 150 200 250 300 350 400
REF
)
REF
voltage is increased, the
www.national.com