Specifications of POWR1014A-B-EVN

Main Purpose
Power Management, Power Supply Supervisor/Tracker/Sequencer
Embedded
No
Utilized Ic / Part
ispPAC-POWR1014A
Primary Attributes
4x15 proto area, One 1x8 and Two 2x20 Expansion Headers
Secondary Attributes
LED Status Indicators
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
220-1158
Lattice Semiconductor
Table 1. Demo Design Sequencing Program (for Reference Only)
5. Choose Tools > Compile LogiBuilder Design. After a few moments the JEDEC programming file is output.
6. From the toolbar launch JED to download and save the file.
Note: PAC-Designer may not recognize files that have certain characters such as spaces or periods in the directory
path.
To program the device using a <demo>.jed file:
1. From the Start menu run ispVM System.
2. Choose Options > Cable and I/O Port Setup...
3. Make the following selections:
4. Choose ispTools > Scan Chain.
5. Highlight the POWR1014A, right-click and choose Edit Device...
6. From the Set Device Operations section, click the Browse button.
7. Download the .jed file either downloaded from the Lattice web site or file compiled using PAC-Designer by
8. Select the device to be programmed by highlighting and then right-clicking and choose Set Device Opera-
9. From the toolbar select Go to program device
Programming requires about 20-40 seconds. A small timer window will appear to show elapsed programming time.
At the end of programming, the configuration setup window should show a “PASS” in the Status column.
Step
7
8
9
Click OK.
ispVM appears.
The Cable and I/O Port Setup dialog appears.
Cable Type: USB2
Port Setting: FTUSB-0
Click OK.
The New Scan Configuration Setup window appears. The POWR1014A appears in the device list.
The Device Information dialog appears.
The Open Data File dialog appears.
browsing to the <Demo Dir>\project folder, selecting <Demo>.jed, and clicking OK.
tions. From the Operation list choose Flash Erase, Program, Verify.
Go to Step 3
Begin shut-down sequence
Halt (end-of-program)
Instruction
6
Outputs
POWR1014A Breakout Board
Evaluation Kit User’s Guide
Int.
0
0
0
Enter loop to alter sequence of
OUT4 through OUT14.
Flashes odd then even LEDs.
Comment