HXS 50-NP LEM USA Inc, HXS 50-NP Datasheet

SENSOR CURRENT 50A 5V MOD

HXS 50-NP

Manufacturer Part Number
HXS 50-NP
Description
SENSOR CURRENT 50A 5V MOD
Manufacturer
LEM USA Inc
Series
HXSr
Datasheet

Specifications of HXS 50-NP

Current - Sensing
±50A
Sensitivity
-
Current - Supply
22mA
Sensor Type
Open Loop Hall Effect
Voltage - Supply
5V
Output
-
Frequency
50kHz
Polarization
Bidirectional
Operating Temperature
-40°C ~ 85°C
Package / Case
Module
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
398-1026-5
LEM Components
Current Transducer HXS 50-NP
For the electronic measurement of currents : DC, AC, pulsed, mixed,
with a galvanic isolation between the primary circuit (high power)
and the secondary circuit (electronic circuit).
I
I
V
V
R
R
C
V
I
X
TCV
TCV
TCV
TC
V
t
t
di/dt
f
T
T
dCp
dCl
CTI
m
All Data are given with a R
PN
P
C
ra
r
A
S
OUT
REF
C
OM
OUT
L
L
L
Electrical data
Accuracy - Dynamic performance data
General data
OUT
REF
OUT
G
/ V
Primary nominal r.m.s. current
Primary current measuring range
Analog output voltage @ I
Internal Reference
Output load resistance
Output impedance
Max. output capacitive load
Supply voltage (± 5 %)
Current consumption @ V
Accuracy
Linearity 0 .. I
Thermal drift of V
Thermal drift of V
Thermal drift of the gain
Residual voltage @ I
Reaction time @ 10 % of I
Response time @ 90 % of I
di/dt accurately followed
Output noise (DC ..10 kHz)
Frequency bandwidth (-3 dB)
Ambient operating temperature
Ambient storage temperature
Creepage distance
Clearance distance
Comparative tracking index (Group I )
UL94 classification
Mass
Standards
REF
Thermal drift of V
2)
.. 3 x I
@ I
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without previous notice.
PN
(DC .. 1 MHz)
PN
PN
, T
OUT
REF
OUT
1)
L
A
@ I
P
= 10 k
- Output voltage
= 25°C
/ V
= 0, after an overload of 3 x I
V
V
REF
REF
P
REF
I
= 0
P
P
C
PN
Output impedance
Load impedance
@ I
= 0
= 5 V
PN
3)
P
= 0
45001
PN DC
typ. 200
±50
±150
V
V
2.5 ± 0.025
5
22
<±1
< 3
< 5
> 50
< 15
< 40
DC .. 50
- 40 .. + 85
- 40 .. + 85
> 5.5
> 5.5
> 600
V0
10
EN 50178
±0.05
±0.5
±0.4
±0.01
±0.2
±1
±1
REF
REF
2
10
1
200
± (0.625·I
± 0.0125
% of reading/K
(97-10-01)
% of I
% of I
% of I
% of I
P
m V p p
m V p p
/I
mV/K
mV/K
PN
A/µs
%/K
m m
m m
kHz
mA
) V
k
k
µF
°C
°C
µs
µs
PN
PN
PN
PN
A
A
V
V
V
V
g
I
Features
Advantages
Applications
PN
Hall effect measuring principle
Multirange current transducer
through PCB pattern lay-out
Galvanic isolation between primary
and secondary circuit
Isolation test voltage 2500V
Low power consumption
Extremely low profile, 10mm
Single power supply +5V
Fixed offset & gain
Small size and space saving
Only one design for wide current
ratings range
High immunity to external
interference.
Internal & external reference
AC variable speed drives
Static converters for DC motor drives
Battery supplied applications
Uninterruptible Power Supplies
(UPS)
Switched Mode Power Supplies
(SMPS)
Power supplies for welding
applications.
= 12.5 - 25 - 50 A
www.lem.com
050906/5
Page 1/3

Related parts for HXS 50-NP

HXS 50-NP Summary of contents

Page 1

... Current Transducer HXS 50-NP For the electronic measurement of currents : DC, AC, pulsed, mixed, with a galvanic isolation between the primary circuit (high power) and the secondary circuit (electronic circuit). Electrical data I Primary nominal r.m.s. current PN I Primary current measuring range P V Analog output voltage @ I ...

Page 2

... Current Transducer HXS 50-NP Isolation characteristics V Nominal Voltage b with IEC 61010-1 standards and following conditions - Single insulation - Over voltage category III - Pollution degree 2 - Heterogeneous field V Nominal Voltage b with EN 50178 standards and following conditions - Reinforced insulation - Over voltage category III - Pollution degree 2 ...

Page 3

... Dimensions HXS 50-NP (in mm 0.0394 inch) 4-0.5*0.25 Number of primary turns Mechanical characteristics General tolerance Fastening & connection of primary jumper Recommended PCB hole Fastening & connection of secondary Recommended PCB hole Remarks V is positive when I flows from terminals (IN) to OUT P terminals (OUT). Temperature of the primary conductors should not exceed 100° ...

Related keywords