1SVR011701R2500 ABB, 1SVR011701R2500 Datasheet
1SVR011701R2500
Specifications of 1SVR011701R2500
Related parts for 1SVR011701R2500
1SVR011701R2500 Summary of contents
Page 1
Analog signal converters CC range Serial data converters ILPH range Content Analogue Signal Converters CC-range Benefi ts and advantages .................................................................................................... 5/ 4 Application ......................................................................................................................... 5/ 5 Approvals and marks ......................................................................................................... 5/ 5 Ordering details Analog standard signal converters ...
Page 2
Product range for analog signal processing 5 CC-U range ½ 8 different standard signal outputs on one device ½ Input and output side universally confi gurable ½ Also available with 2 threshold relay outputs ½ Adjustment and operating elements on ...
Page 3
Analog signal converters CC range Application, Approvals and marks Applications for analog signal processing and correct solution using CC-E and CC-U converters Nearly every process includes a control system that receives data by means of analog signals and then evaluates ...
Page 4
CC-E/STD CC-E V green LED - supply voltage Gain adjustment Offset adjustment DIP switch for input and output confi guration (only available on universal devices 1604 Class I, Div.2 (universal device) 5/6 2CDC110004C0207 Analog standard signal ...
Page 5
Current/current isolator CC-E I/I-1 and CC-E I/I-2 Ordering details Loop-powered current/current isolator without external power supply for analog current signals of 0-20 mA and 4-20 mA ½ Electrical isolation between input and output ½ Very low internal voltage drop ½ ...
Page 6
CC-U/STD Plug-in terminals Gain: Coarse adjustment Gain: Fine adjustment Offset adjustment U: green LED - supply voltage Marker label 5 5/8 2CDC110004C0207 Analog standard signal converter CC-U/STD Ordering details CC-U/STD universal signal converter with 3-way electrical isolation ½ More than ...
Page 7
Analog standard signal converter CC-U/STDR with relay output Ordering details CC-U/STDR universal signal converter for standard signals, with 2 threshold relay outputs and with 3-way electrical isolation ½ Standard signal converter with 7 setting ranges ½ 2 threshold relay outputs ...
Page 8
CC-E/RTD Gain adjustment Offset adjustment U: green LED - supply voltage DIP switch for input and output confi guration (only available on universal devices 1604 Class I, Div.2 (universal device) 5/10 2CDC110004C0207 Temperature signal converter for RTD ...
Page 9
Temperature signal converter for RTD sensors CC-U/RTD Ordering details CC-U/RTD universal signal converter for PT10, PT100, PT1000 temperature sensors (acc. to IEC 751 and JIS C 1604 ½ Confi gurable output signal response on input signal interruption (low / high ...
Page 10
CC-U/RTDR Plug-in connecting terminals Threshold value for R1 Hysteresis for R1 Threshold value for R2 Hysteresis for R2 U: green LED - supply voltage R2: yellow LED - Relay 2 energized R1: yellow LED - Relay 1 energized 5 Marker ...
Page 11
Temperature signal converter for thermocouples CC-E/TC Ordering details CC-E/TC analog signal converter for thermocouple signals of the types J and K with 3-way electrical isolation ½ 2 universally confi gurable devices (type CC-E/TC) ½ 2x6 single-function devices ½ "Plug and ...
Page 12
CC-U/TC Plug-in connecting terminals Gain: Coarse adjustment Gain: Fine adjustment Offset adjustment U: green LED - supply voltage Marker label 5 5/14 2CDC110004C0207 Temperature signal converter for thermocouples CC-U/TC Ordering details CC-U/TC universal signal converter for thermocouples with 3-way electrical ...
Page 13
Temperature signal converter for thermocouples CC-U/TCR with relay output Ordering details CC-U/TCR universal signal converter for thermocouples, with 2 threshold relay outputs and 3-way electrical isolation ½ Temperature signal converter for thermocouples of the types ½ ...
Page 14
CC-E/I Gain adjustment Offset adjustment U: green LED - supply voltage DIP switch for input and output confi guration (only available on universal devices 1604 Class I, Div.2 (universal device) 5/16 2CDC110004C0207 Measuring converter for sinusoidal and ...
Page 15
Measuring converter for sinusoidal currents CC-E I Ordering details CC 0-1 A, 0-5 A, output 4-20 mA ½ Measuring converter for sinusoidal currents (0-1 A, 0-5 A) ½ Measuring range selection by front-face sliding switch ½ 4-20 mA ...
Page 16
CC-U/I Plug-in connecting terminals Gain adjustment Offset adjustment U: green LED - supply voltage Marker label 5 5/18 2CDC110004C0207 Measuring converter for current RMS values CC-U/I Ordering details CC-U/I universal measuring converter for RMS values of 0-1 A and 0-5 ...
Page 17
Measuring converter for voltage RMS values CC-U/V Ordering details CC-U/V universal measuring converter for RMS values of 0-600 V, with 3-way electrical isolation ½ RMS converter for voltage signals up to 600 V of any wave form (DC, DC with ...
Page 18
ADP.01 3A11 20 .787” MAR.01 7 .275” 22,5 3,5 .138” .886” front-to-back size 107 5 Sealable cover COV.01 5/20 2CDC110004C0207 Analog signal converters Accessories for CC-U range Ordering details Accessories Adapter for screw mounting Type for ...
Page 19
Analog signal converters CC-E/STD, CC-E x/x, CC-E/RTD, CC-E/TC Technical data Type Input circuits - Analog inputs Input signal Rated input range Limitation of input signals Infl uence of line resistance Gain adjustment range Offset adjustment range Input impedance Suppression at ...
Page 20
Type Input circuits - Analog inputs Input current I IN Min. input current Max. input current Input voltage U IN Input voltage drop U i Max. input voltage Output circuits Output current I OUT Output load R L Output voltage ...
Page 21
Analog signal converters CC-U/STD, CC-U/RTD, CC-U/TC Technical data Type Input circuits - Analog inputs Input signal Limitation of input signals Rated input range Infl uence of line resistance Gain adjustment range (universal devices) Offset adjustment range (universal devices) Input impedance ...
Page 22
Type Input circuits - Analog inputs Measuring signal / input range Input resistance Adjustable threshold Adjustable hysteresis Repeat accuracy (constant parameters) Output circuits - Relay outputs Rated switching voltage Rated switching AC12 (resistive) 230 V current AC15 (inductive) 230 V ...
Page 23
Analog signal converters CC-E/I, CC-E I Technical data Type Input circuits - Analog inputs Rated input range Measuring frequency Overload capacity of input range 1 inputs input range 2 Gain adjustment range Offset adjustment range Input impedance / resistance Output ...
Page 24
Type Input circuits - Analog inputs Rated input range Measuring frequency Overload capacity of inputs Gain adjustment range Offset adjustment range Input impedance / resistance Output circuits - Analog outputs Output signal Output load Accuracy 1) Temperature coeffi cient Residual ...
Page 25
Analog signal converters CC-E, CC-U Technical diagr., Connection diagr., Dimensional drawings Technical diagrams Load limit curves CC-U/xxR Resistive AC load Resistive DC load Derating curve 1.0 0.9 0.8 F 0.7 0.6 0.5 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 ...
Page 26