Specifications of 1SVR011701R2500

Input Type
RT100 Temperature Sensors
Output Accuracy
± 0.5%
Supply Voltage
24VDC
No. Of Channels
1
Mounting Type
Din Rail
Isolation Input
Isolated
External Depth
102mm
Rohs Compliant
Yes
Svhc
No SVHC (20-Jun-2011)
5
5/14
2CDC110004C0207
CC-U/TC
Plug-in connecting
terminals
Gain: Coarse adjustment
Gain: Fine adjustment
Offset adjustment
U: green LED -
supply voltage
Marker label
Temperature signal converter for thermocouples
CC-U/TC
Ordering details
CC-U/TC universal signal converter for thermocouples with 3-way electrical isolation
½
½
½
½
½
½
½
DIP switch settings
Type
CC-U/TC
• Accessories ........................................................................... 5/20
• Technical data ....................................................................... 5/21
3.33...16.66 mA
-3.75...+1.25 V
-6.66...+6.66 V
-3.33...+3.33 V
2.5...12.5 mA
-10...+3.33 V
1.25...6.25 V
1.66...8.33 V
0...13.33 mA
125...625 μA
166...833 μA
-7.5...+2.5 V
100...500 μA
-5...+1.66 V
Temperature signal converter for thermo-
couples of the types K, J, T, S, E, N, R, B
Continuously adjustable voltage signal input
0-10 mV and 0-50 mV
Differential temperature meas. possible
Confi gurable output signal response on input
signal interruption (low fail safe / high fail safe)
Adjustment and operating elements on the
front-side
Short-circuit proof signal outputs
Plug-in connecting terminals for inputs,
outputs and supply
-10...+10 V
0...0.5 mA
0...800 μA
0...400 μA
0.2...1 mA
0...6.66 V
-10...-2 V
0...20 mA
4...20 mA
0...10 mA
0...666 μA
0...16 mA
2...10 mA
Output
-5...+5 V
-10...0 V
-5...-1 V
0...1 mA
0...8 mA
0...10 V
2...10 V
-5...0 V
-8...0 V
-4...0 V
0...5 V
1...5 V
0...8 V
0...4 V
no influence
Legend
OFF
ON
1 2
Switch 3
3
4
5 6
Rated supply voltage
110-240 V AC
24-48 V DC
Characteristic curves
-10000
-15000
80000
75000
70000
65000
60000
55000
50000
45000
40000
35000
30000
25000
20000
15000
10000
-5000
5000
0
Thermocouple voltages depending on the temperature
Type
mV
K
J
T
S
E
N
R
B
High fail safe *)
Low fail safe *)
0-250...1350 °C
-150-0...400 °C
0-250...1550 °C
0-200...1000 °C
0-200...1300 °C
0-250...1350 °C
0-450...1700 °C
0-700...1750 °C
0-100...900 °C
0-100...750 °C
0-100...400 °C
0-100...700 °C
0-100...650 °C
0-10...50 mV
0-2...10 mV
Input
Range
1)
1 2
Switch 1
1SVR 040 004 R0700
1SVR 040 005 R0000
3
Wiring instruction
4
• Dimensional drawings ............................................................ 5/27
Typ T
5 6 1 2
Order code
1)
Switch 2
3
4
Temperatur [°C]
5 6
without cold-junction compensation:
switch SW2.2 = OFF
supply
Typ E
*) Detection of input signal
interruptions:
If the input signal circuit is inter-
rupted, the output signal changes
to the adjusted minimum value
(low fail safe) or maximum value
(high fail safe).
Pack. unit
pieces
Typ J
1
1
Typ N
Typ K
1 piece

R
R
Price
Burden
Burden
Typ R
Typ B
4.7 k
600
Typ S

Related parts for 1SVR011701R2500