LM81CIMTX-3 National Semiconductor, LM81CIMTX-3 Datasheet - Page 21

LM81CIMTX-3

Manufacturer Part Number
LM81CIMTX-3
Description
Manufacturer
National Semiconductor
Datasheet

Specifications of LM81CIMTX-3

Monitored Voltage 1 (typ)
2.5/3.3/5/12V
Battery Backup Switching
No
Watchdog Timer
Yes
Chip Enable Signals
No
Manual Reset
No
Package Type
TSSOP
Operating Supply Voltage (min)
2.8V
Operating Supply Voltage (max)
3.8V
Operating Temp Range
-40C to 125C
Operating Temperature Classification
Automotive
Power Fail Detection
No
Mounting
Surface Mount
Pin Count
24
Lead Free Status / Rohs Status
Not Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
LM81CIMTX-3
Manufacturer:
ADI
Quantity:
50 000
Part Number:
LM81CIMTX-3
Manufacturer:
NS/国半
Quantity:
20 000
Company:
Part Number:
LM81CIMTX-3
Quantity:
2 300
Part Number:
LM81CIMTX-3/NOPB
Manufacturer:
ICT
Quantity:
6 235
Part Number:
LM81CIMTX-3/NOPB
Manufacturer:
TI/德州仪器
Quantity:
20 000
Functional Description
Extended Repetitive Interrupt Mode is shown in Figure 14
and operates in the following way: Once activated, all inter-
rupts remain activated until reset by a read of the Interrupt
Status Register 1. Once activated all T_CRIT_A interrupts
remain activated until reset by a read of the Extended Mode
Register 1. Temperature conversion data less than or equal
to T
activated until the temperature data exceeds (T
T
continue to be activated at the end of a conversion until the
temperature data is less than or equal to (T
T_CRIT_A interrupts are activated when the temperature
exceeds T_CRIT. T_CRIT_A interrupts will no longer be
activated if the temperature data at the end of a conversion
is less than or equal to( T_CRIT − T
Extended One-Time Interrupt Mode is shown in Figure 15
and operates in the following way: Once activated all inter-
rupts remain activated until reset by a read of the Interrupt
Status Register 1. Once activated all T_CRIT_A interrupts
remain activated until reset by a read of the Extended Mode
Register 1. An interrupt will be activated when the data of a
temperature conversion is less than or equal to T
rupt cannot again be activated until the data from a tempera-
ture conversion is greater than (T
will be activated when the data of a temperature conversion
is greater than T
until the data of a temperature conversion is less than or
equal to (T
when the data from a temperature conversion is greater than
T_CRIT. Activation of an T_CRIT_A interrupt cannot occur
until the data from a temperature conversion is less than or
equal to ( T_CRIT − T
*
*
Note: Interrupt resets occur only when interrupt Status Register 1 is read.
Note: Interrupt resets occur only when interrupt Status Register 1 is read.
HYST
LOW
FIGURE 14. Extended Repetitive Interrupt Mode
). Exceeding T
FIGURE 15. Extended One-Time Interrupt
will activate interrupt. Interrupt will continue to be
HIGH
− T
HIGH
HYST
HIGH
. Interrupt cannot again be activated
HYST
). T_CRIT_A interrupt is activated
).
activates interrupt. Interrupt will
LOW
HYST
+ T
(Continued)
).
HYST
HIGH
). An interrupt
DS100072-21
LOW
− T
DS100072-20
LOW
. Inter-
HYST
+
).
21
Extended Comparator Mode is shown in Figure 16 and
operates in the following way: Interrupt is activated when the
data from a temperature conversion is less than or equal to
T
conversion exceeds (T
activate interrupt. This interrupt will be reset when data from
a temperature conversion is less than or equal to (T
T
ture exceeds T_CRIT. T_CRIT_A remains active until the
data from a temperature conversion is less than or equal to
(T_CRIT − T
*
Note: Interrupt resets occur only when interrupt Status Register 1 is read.
LOW
HYST
. Interrupt is reset when the data from a temperature
). T_CRIT_A interrupt is activated when the tempera-
FIGURE 16. Extended Comparator Mode
HYST
) resets it.
LOW
+ T
HIGH
). Exceeding T
DS100072-19
www.national.com
HIGH
HIGH
will

Related parts for LM81CIMTX-3