Specifications of ATA5811-PLQX

Operating Temperature (min)
-40C
Operating Temperature (max)
105C
Operating Temperature Classification
Industrial
Product Depth (mm)
7mm
Product Height (mm)
0.9mm
Product Length (mm)
7mm
Lead Free Status / Rohs Status
Compliant
TX/RX Data Buffer
Control Register
Control Register 1 (ADR 0)
34
ATA5811/ATA5812 [Preliminary]
The TX/RX data buffer is used to handle the data transfer during RX and TX operations.
To use the transceiver in different applications it can be configured by a connected
microcontroller via the 4-wire serial interface.
Table 14. Control Register 1 (Function of Bit 7 and Bit 6 in RX Mode)
Table 15. Control Register 1 (Function of Bit 7 and Bit 6 in TX Mode)
Table 16. Control Register 1 (Function of Bit 5)
Table 17. Control Register 1 (Function of Bit 4)
IR1
IR1
AVCC_EN
0
0
1
1
0
0
1
1
FS
0
1
0
1
IR0 Function (RX Mode)
IR0 Function (TX Mode)
0
1
0
1
0
1
0
1
Pin IRQ is set to 1 if 4 received bytes are in the TX/RX data buffer or a receiving
error occurred
Pin IRQ is set to 1 if 8 received bytes are in the TX/RX data buffer or a receiving
error occurred
Pin IRQ is set to 1 if 12 received bytes are in the TX/RX data buffer or a receiving
error occurred (default)
Pin IRQ is set to 1 if a receiving error occurred
Pin IRQ is set to 1 if 4 bytes still are in the TX/RX data buffer or the TX data buffer
is empty
Pin IRQ is set to 1 if 8 bytes still are in the TX/RX data buffer or the TX data buffer
is empty
Pin IRQ is set to 1 if 12 bytes still are in the TX/RX data buffer or the TX data buffer
is empty (default)
Pin IRQ is set to 1 if the TX data buffer is empty
Function
(default)
Enables AVCC, if the ATA5811/
Function
433/868 MHz
315 MHz
ATA5812
is in AUX mode
4689B–RKE–04/04

Related parts for ATA5811-PLQX