MI-AIM-M1 Vicor Corporation, MI-AIM-M1 Datasheet

no-image

MI-AIM-M1

Manufacturer Part Number
MI-AIM-M1
Description
Military COTS Component Front-end Modules
Manufacturer
Vicor Corporation
Datasheet
The AC input module interfaces directly with
AC mains to provide line rectification, EMI
filtering, transient protection, and inrush
limiting. These front-end modules accept 115
Vac and provide 250 W of output power for
any of Vicor's MI-x7x family of standard and
junior size modules.
The MI-AIM meets CE102 conducted emissions
requirements of MIL-STD-461D/E and the
transient and spike requirements of
MIL-STD-704A-F.
Fully encapsulated in Vicor’s industry
standard package, the MI-AIM meets
MIL-STD-810 Environmental testing
requirements for humidity, fungus, salt- fog,
explosive atmosphere, acceleration, vibration
and shock.
Example: MI - AIM - M1
Examples:
MI - AIM - M1 -
MI - AIM - M1 -
MI - AIM - M1 -
MI - AIM - M1 -
Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715
Inputs: 115 Vac 60/400 Hz
Output power: 250 W
MIL-STD-704A-F input transient
protection
MIL-STD-461D/E EMI compliant
MIL-STD-810, MIL-STD-202
environments
Compatible with MI-x7x family
modules
Efficiency: 95%
Operating temperature to 100˚C
Size: 2.28" x 2.4" x 0.5"
(57,9 x 61,0 x 12,7 mm)
Slotted baseplate
Flangeless baseplate, option suffix:
Finned heat sink, option suffix:
, 0.25" fins, longitudinal
, 0.50" fins, longitudinal
, 0.25" fins, transverse
, 0.50" fins, transverse
or
Set your site on VICOR at www.vicorpower.com
AC Input Front End Module
Parameter
AC line input
Inrush current
Transient input
Conducted EMI
Spikes
Parameter
Output power
Hold-up time
Efficiency
Model Number
MI-AIM-M1
MI-AIM-I1
(V)
(f)
Compatible MI-Series
MI-AIM, AC Input Front End Module
MI-27x /MI-J7x
MI-27x /MI-J7x
Min
Min
85
47
80
CE102 per MIL-STD-461 D/E
Application specific
60/400
95%
Typ
115
Typ
250
Converter
M–grade
I–grade
Max
Max
140
440
180
480
±50
40
Operating Temp (°C)
A, peak
–55 to +85 /+100
–40 to +85 /+100
Vrms
Vrms
Unit
Unit
Vac
Hz
Hz
%
W
57,9 x 61,0 x 12,7 mm
2.28 x 2.4 x 0.5 in
Notes
Operates over entire range
125 Vac
20 ms, per MIL-STD-704A
100 ms, per MIL-STD-704A
Peak, per MIL-STD-704A
100 – 125 Vac; 60 Hz
Nominal line voltage, 50 µs
Notes
100°C
A function of external
capacitance and power
115 Vac; 60/400 Hz
Rev. 1.2
Actual size:
Storage Temp (°C)
–65 to +100 /+125
–55 to +100/+125
Page 1 of 5

Related parts for MI-AIM-M1

MI-AIM-M1 Summary of contents

Page 1

... Spikes Parameter Min Typ Output power 250 Hold-up time Application specific Efficiency 95% Model Number Compatible MI-Series Converter MI-AIM-M1 MI-27x /MI-J7x M–grade MI-AIM-I1 MI-27x /MI-J7x I–grade MI-AIM, AC Input Front End Module Actual size: 2.28 x 2.4 x 0.5 in 57,9 x 61,0 x 12,7 mm Max Unit Notes ...

Page 2

... Altitude - Method 500.2 70,000 Humidity - Method 507.2 88/ 240 Acceleration - Method 513.3 9.0 Vibration - Method 514.3 20 Shock - Method 516.3 40 RELIABILITY — MIL-HDBK-217F (MI-AIM-M1) Parameter Min 25°C Ground Benign: G.B. 50°C Naval Sheltered: N.S. 65°C Airborne Inhabited Cargo: A.I.C. GENERAL SPECIFICATIONS Parameter Min Size ...

Page 3

... Explosive Atmosphere MIL-STD-810C, Method 511.1, Procedure I MIL-STD-810D, Method 514.3, Procedure I, category 6, helicopter MIL-STD-810D, Method 514.3 random: 10 – 300 /Hz, 2000 Hz @ 0.002 Hz, 3.9 total G rms Vibration /axis. Sine 6.6 g, 120 Hz @ 5.0 g, 16.0 total G rms, 3 axes MIL-STD-810E, Method 514.4, Table 514.4-VII, ±6 db/octave, 7.7 G rms, 1hr/axis MIL-STD-810D, Method 516 ...

Page 4

... 0.47 µF N/C L2/N [b] 1,200 µF max. Fuse 1: 7A F03A type recommended Fuse 2: MI-x7x-xx – Buss PC – TRON 2 – (450 V) Figure 1 — MI-AIM Connection diagram, typical application in (57,9) (mm) .49 (12,4) .65 .30±.015 (16,5) (7,6)±(0,38 2.10 MI-AIM VI-AIM ...

Page 5

... Vicor products are guaranteed for two years from date of shipment against defects in material or workmanship when in normal use and service. This warranty does not extend to products subjected to misuse, accident, or improper application or maintenance. Vicor shall not be liable for collateral or consequential damage. This warranty is extended to the original purchaser only ...

Related keywords