V375A5C400B Vicor Corporation, V375A5C400B Datasheet - Page 2

no-image

V375A5C400B

Manufacturer Part Number
V375A5C400B
Description
Manufacturer
Vicor Corporation
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
V375A5C400B
Manufacturer:
VICOR
Quantity:
10
Part Number:
V375A5C400BL
Manufacturer:
ABB
Quantity:
12
Part Number:
V375A5C400BL
Manufacturer:
VICOR
Quantity:
20 000
Part Number:
V375A5C400BN4
Manufacturer:
VICOR
Quantity:
228
Part Number:
V375A5C400BN4
Manufacturer:
VICOR
Quantity:
20 000
Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715
Electrical characteristics apply over the full operating range of input voltage, output load (resistive) and baseplate temperature,
unless otherwise specified. All temperatures refer to the operating temperature at the center of the baseplate.
Operating input voltage
Input surge withstand
Undervoltage turn-on
Undervoltage turn-off
Overvoltage turn-off/on
Disabled input current
Output voltage setpoint
Line regulation
Temperature regulation
Power sharing accuracy
Programming range
Baseplate to sink; flat, greased surface
Baseplate to sink; thermal pad (P/N 20265)
Baseplate to ambient
Baseplate to ambient; 1000 LFM
Thermal capacity
2 V
3.3 V
5 V
8 V
12 V
15 V
24 V
28 V
32 V
36 V
48 V
54 V
For important information relative to applications where the converter modules are subject to continuous dynamic loading,
contact Vicor applications engineering at 800-927-9474.
Set your site on VICOR at vicorpower.com
204.7
429.2
250
10
±0.002
242.5
212.2
446.3
±0.02
375
±2
-0.5 to 10.9
-0.5 to 16.1
-0.5 to 20.0
-0.5 to 31.7
-0.5 to 36.9
-0.5 to 41.9
-0.5 to 47.1
-0.5 to 62.9
-0.5 to 70.2
-0.5 to 3.1
-0.5 to 4.7
-0.5 to 7.0
±0.005
247.5
467.5
±0.2
425
500
110
1.1
± 5
1
375V Maxi Family
% Vout nom
0.08
0.07
165
4.9
1.1
% / °C
Vdc
Vdc
Vdc
Vdc
Vdc
Vdc
Vdc
Vdc
Vdc
Vdc
Vdc
Vdc
Vdc
Vdc
Vdc
Vdc
Vdc
mA
%
%
%
<100 ms
PC pin low
Nominal input; full load; 25°C
Low line to high line; full load
Over operating temperature range
10 to 100% of full load
Of nominal output voltage. For trimming below 90%
of nominal, a minimum load of 10% of maximum
rated power may be required.
Externally applied
Externally applied
Externally applied
Externally applied
Externally applied
Externally applied
Externally applied
Externally applied
Externally applied
Externally applied
Externally applied
Externally applied
Watt-sec/°C
°C/Watt
°C/Watt
°C/Watt
°C/Watt
Rev. 8.4
Page 2 of 14