PAH50S48-2.5 TDK Corporation, PAH50S48-2.5 Datasheet - Page 20

no-image

PAH50S48-2.5

Manufacturer Part Number
PAH50S48-2.5
Description
Manufacturer
TDK Corporation
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
PAH50S48-2.5
Manufacturer:
LAMBDA
Quantity:
1 000
Part Number:
PAH50S48-2.5
Quantity:
60
Part Number:
PAH50S48-2.5/V
Manufacturer:
LAMBDA
Quantity:
1 000
CC-E
09XX
10XX
KWD
PAE
PAF
PAH
PAQ
PF-A
PMH
3101
KWS
PFE
PH
CE-
CE-
CE-
KS
B-162
PAH
(*10) External components are needed for operation.
Function
Environment
Isolation
Standards Safety Standards
Mechanical
ITEMS/UNITS
Output
(*1) At 48VDC, 80% of maximum output current and baseplate temperature = +25℃.
(*2) At 48VDC and maximum output current. baseplate temperature = +25℃.
(*3) 36 - 76VDC, constant load.
(*4) No load - full load, constant input voltage.
(*5) Constant current limiting with automatic recovery.
(*6) Inverter shutdown method, manual reset.
(*7) Ratings - Refer to derating curve on the right.
(*8) Heatsink has to be chosen according to instruction manual.
(*9) Refer to instruction manual.
Input
(Refer to basic connection and instruction manual.)
Voltage Range
Efficiency (typ)
Current (typ)
Nominal Voltage
Maximum Current
Maximum Power
Voltage Setting Accuracy (*2) %
Maximum Line Regulation (*3) mV
Maximum Load Regulation (*4) mV
Temperature Coefficient
Maximum Ripple & Noise (*10) mVp-p
Voltage Adjustable Range (*10)
Over Current Protection (*5)
Over Voltage Protection (*6)(*9)
Remote Sensing
Remote ON/OFF Control (*9)
Parallel Operation
Series Operation
Operating Temperature
Storage Temperature
Operating Humidity
Storage Humidity
Vibration
Shock
Cooling
Withstand Voltage
Isolation Resistance
Weight (typ)
Size (W x H x D)
450S48
- Load(%) is percent of maximum output current.
- Refer to instruction manual.
MODEL
(*2)
(*9)
(*9)
(*9)
(*7) ℃
(*8)
(*1) %
PAH450S48 Specifications
VDC
%RH
%RH
mm
W
V
A
A
g
Amplitude 0.825mm constant (maximum 49.0m/s²) X,Y,Z 1 hour each
More than 100MΩ at 25℃ and 70%RH Output-Baseplate...500VDC
PAH450S48-28
Approved by UL60950-1, CSA C22.2 No.60950-1, EN60950-1.
Input-Baseplate : 1.5kVDC, Input-Output : 1.5kVDC for 1min.
-40%, +18%
-40 to +100 (Baseplate) Ambient temperature min=-40
10.3
448
280
28
16
56
56
At no operating, 10-55Hz (sweep for 1min.)
61 x 12.7 x 57.9 (Refer to outline drawing)
Possible (SHORT : ON OPEN : OFF)
Output-Baseplate : 500VDC for 1min.
5 - 95 (No dewdrop)
5 - 95 (No dewdrop)
Conduction cooled
105% - 140%
125% - 145%
36 - 76 VDC
-40 to +100
196.1m/s²
0.02%/℃
Possible
Possible
100
±1
92
-
・All specifications are subject to change without notice.
PAH450S48-48
-40%, +20%
451.2
10.4
480
9.4
48
96
96

Related parts for PAH50S48-2.5