AT89LP6440 Atmel Corporation, AT89LP6440 Datasheet - Page 67

no-image

AT89LP6440

Manufacturer Part Number
AT89LP6440
Description
Manufacturer
Atmel Corporation
Datasheet

Specifications of AT89LP6440

Flash (kbytes)
64 Kbytes
Max. Operating Frequency
20 MHz
Cpu
8051-1C
Max I/o Pins
38
Spi
1
Twi (i2c)
1
Uart
1
Adc Channels
8
Adc Resolution (bits)
10
Adc Speed (ksps)
153.8
Sram (kbytes)
4.25
Eeprom (bytes)
8192
Self Program Memory
IAP
Operating Voltage (vcc)
2.4 to 3.6
Timers
3
Isp
SPI/OCD
Watchdog
Yes

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
AT89LP6440-20AU
Manufacturer:
Cirrus
Quantity:
89
Part Number:
AT89LP6440-20AU
Manufacturer:
Atmel
Quantity:
10 000
Part Number:
AT89LP6440-20JU
Manufacturer:
Atmel
Quantity:
103
Part Number:
AT89LP6440-20JU
Manufacturer:
Atmel
Quantity:
10 000
Part Number:
AT89LP6440-20MU
Manufacturer:
Atmel
Quantity:
987
12.4
3706C–MICRO–2/11
Baud Rate Generator
Figure 12-7. Timer 2 Waveform: Dual Slope Modes
Timer 2 is selected as the baud rate generator by setting TCLK and/or RCLK in T2CON
12-3). Note that the baud rates for transmit and receive can be different if Timer 2 is used for the
receiver or transmitter and Timer 1 is used for the other function. Setting RCLK and/or TCLK
puts Timer 2 into its baud rate generator mode, as shown in
The baud rate generator mode is similar to the auto-reload mode, in that a rollover in TH2
causes the Timer 2 registers to be reloaded with the 16-bit value in registers RCAP2H and
RCAP2L, which are preset by software.
The baud rates in UART Modes 1 and 3 are determined by Timer 2’s overflow rate according to
the following equation.
The Timer can be configured for either timer or counter operation. In most applications, it is con-
figured for timer operation (CP/T2 = 0). The baud rate formulas are given below.
where (RCAP2H, RCAP2L) is the content of RCAP2H and RCAP2L taken as a 16-bit unsigned
integer.
Timer 2 as a baud rate generator is shown in
TCLK = 1 in T2CON. Note that a rollover in TH2 does not set TF2 and will not generate an inter-
rupt. Note too, that if EXEN2 is set, a 1-to-0 transition in T2EX will set EXF2 but will not cause a
reload from (RCAP2H, RCAP2L) to (TH2, TL2). Thus when Timer 2 is in use as a baud rate gen-
T2CM = 01B
T2CM = 00B
EXF2
MAX
MAX
TOP
TOP
MIN
MIN
Modes 1 and 3 Baud Rates
Modes 1, 3
Modes 1, 3
Baud Rate
Baud Rate
=
=
------------------------------------------------------------------------------------------------------------------ -
16
-------------------------------------------------------------------------------------------------------------------------------- -
16
×
×
(
(
TPS
TPS
Figure
T2CM
T2CM
=
+
+
Oscillator Frequency
Timer 2 Overflow Rate
----------------------------------------------------------- -
1-0
1-0
1
1
Oscillator Frequency
12-8. This figure is valid only if RCLK or
)
)
= 10B
= 11B
×
×
[
[
(
65536
RCAP2H RCAP2L
Figure
AT89LP3240/6440
16
12-8.
(
RCAP2H,RCAP2L
,
)
+
TF2 Set
TF2 Set
1
]
)
]
(Table
67