ATtiny43U Atmel Corporation, ATtiny43U Datasheet - Page 149

no-image

ATtiny43U

Manufacturer Part Number
ATtiny43U
Description
Manufacturer
Atmel Corporation
Datasheets

Specifications of ATtiny43U

Flash (kbytes)
4 Kbytes
Pin Count
20
Max. Operating Frequency
8 MHz
Cpu
8-bit AVR
# Of Touch Channels
8
Hardware Qtouch Acquisition
No
Max I/o Pins
16
Ext Interrupts
16
Usb Speed
No
Usb Interface
No
Spi
1
Twi (i2c)
1
Graphic Lcd
No
Video Decoder
No
Camera Interface
No
Adc Channels
4
Adc Resolution (bits)
10
Adc Speed (ksps)
15
Analog Comparators
1
Resistive Touch Screen
No
Temp. Sensor
Yes
Crypto Engine
No
Sram (kbytes)
0.25
Eeprom (bytes)
64
Self Program Memory
YES
Dram Memory
No
Nand Interface
No
Picopower
Yes
Temp. Range (deg C)
-40 to 85
I/o Supply Class
0.7 to 5.5
Operating Voltage (vcc)
0.7 to 5.5
Fpu
No
Mpu / Mmu
no / no
Timers
2
Output Compare Channels
4
Pwm Channels
4
32khz Rtc
No
Calibrated Rc Oscillator
Yes
19.6.8
19.6.9
19.6.10
19.6.11
8048B–AVR–03/09
Programming the Fuse Low Bits
Programming the Fuse High Bits
Programming the Extended Fuse Bits
Programming the Lock Bits
The algorithm for programming the Fuse Low bits is as follows (refer to
on page 145
The algorithm for programming the Fuse High bits is as follows (refer to
Flash” on page 145
The algorithm for programming the Extended Fuse bits is as follows (refer to
Flash” on page 145
Figure 19-5. Programming the FUSES Waveforms
The algorithm for programming the Lock bits is as follows (refer to
page 145
1. A: Load Command “0100 0000”.
2. C: Load Data Low Byte. Bit n = “0” programs and bit n = “1” erases the Fuse bit.
3. Give WR a negative pulse and wait for RDY/BSY to go high.
1. A: Load Command “0100 0000”.
2. C: Load Data Low Byte. Bit n = “0” programs and bit n = “1” erases the Fuse bit.
3. Set BS1 to “1” and BS2 to “0”. This selects high data byte.
4. Give WR a negative pulse and wait for RDY/BSY to go high.
5. Set BS1 to “0”. This selects low data byte.
1. 1. A: Load Command “0100 0000”.
2. 2. C: Load Data Low Byte. Bit n = “0” programs and bit n = “1” erases the Fuse bit.
3. 3. Set BS1 to “0” and BS2 to “1”. This selects extended data byte.
4. 4. Give WR a negative pulse and wait for RDY/BSY to go high.
5. 5. Set BS2 to “0”. This selects low data byte.
RESET +12V
PAGEL/BS1
RDY/BSY
XA1/BS2
for details on Command and Data loading):
DATA
CLKI
XA0
WR
OE
for details on Command and Data loading):
0x40
A
for details on Command and Data loading):
for details on Command and Data loading):
DATA
C
Write Fuse Low byte
XX
0x40
A
DATA
C
Write Fuse high byte
XX
0x40
“Programming the Flash” on
A
“Programming the Flash”
DATA
C
Write Extended Fuse byte
“Programming the
XX
“Programming the
149

Related parts for ATtiny43U