ATxmega192A3U Atmel Corporation, ATxmega192A3U Datasheet - Page 274

no-image

ATxmega192A3U

Manufacturer Part Number
ATxmega192A3U
Description
Manufacturer
Atmel Corporation
Datasheets

Specifications of ATxmega192A3U

Flash (kbytes)
192 Kbytes
Pin Count
64
Max. Operating Frequency
32 MHz
Cpu
8-bit AVR
# Of Touch Channels
16
Hardware Qtouch Acquisition
No
Max I/o Pins
50
Ext Interrupts
50
Usb Transceiver
1
Usb Speed
Full Speed
Usb Interface
Device
Spi
10
Twi (i2c)
2
Uart
7
Graphic Lcd
No
Video Decoder
No
Camera Interface
No
Adc Channels
16
Adc Resolution (bits)
12
Adc Speed (ksps)
2000
Analog Comparators
4
Resistive Touch Screen
No
Dac Channels
2
Dac Resolution (bits)
12
Temp. Sensor
Yes
Crypto Engine
AES/DES
Sram (kbytes)
16
Eeprom (bytes)
2048
Self Program Memory
YES
Dram Memory
No
Nand Interface
No
Picopower
Yes
Temp. Range (deg C)
-40 to 85
I/o Supply Class
1.6 to 3.6
Operating Voltage (vcc)
1.6 to 3.6
Fpu
No
Mpu / Mmu
no / no
Timers
7
Output Compare Channels
22
Input Capture Channels
22
Pwm Channels
22
32khz Rtc
Yes
Calibrated Rc Oscillator
Yes

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ATxmega192A3U-AU
Manufacturer:
MSDS
Quantity:
124
Part Number:
ATxmega192A3U-AU
Manufacturer:
Atmel
Quantity:
10 000
Part Number:
ATxmega192A3U-AUR
Manufacturer:
Atmel
Quantity:
10 000
21.9.4
8331A–AVR–07/11
STATUS - Master Status Register
STOP condition. The ACKACT bit and the CMD bits can be written at the same time, and then
the acknowledge action will be updated before the command is triggered.
Table 21-5.
Writing a command to the CMD bits will clear the master interrupt flags and the CLKHOLD flag.
• Bit 7
This flag is set when a byte is successfully received in master read mode; i.e., no arbitration was
lost or bus error occurred during the operation. Writing a one to this bit location will clear RIF.
When this flag is set, the master forces the SCL line low, stretching the TWI clock period. Clear-
ing the interrupt flags will release the SCL line.
This flag is also cleared automatically when:
• Bit 6
This flagis set when a byte is transmitted in master write mode. The flag is set regardless of the
occurrence of a bus error or an arbitration lost condition. WIF is also set if arbitration is lost dur-
ing sending of a NACK in master read mode, and if issuing a START condition when the bus
state is unknown. Writing a one to this bit location will clear WIF. When this flag is set, the mas-
ter forces the SCL line low, stretching the TWI clock period. Clearing the interrupt flags will
release the SCL line.
The flag is also cleared automatically for the same conditions as RIF.
Bit
+0x03
Read/Write
Initial Value
• Writing to the ADDR register
• Writing to the DATA register
• Reading the DATA register
• Writing a valid command to the CMD bits in the CTRLC register
CMD[1:0]
00
01
10
11
RIF: Read Interrupt Flag
WIF: Write Interrupt Flag
R/W
RIF
7
0
CMD bits description.
WIF
R/W
Configuration
6
0
BYTEREC
NOACT
START
Group
STOP
CLKHOLD
R
5
0
RXACK
R
4
0
MODE
W
X
X
R
X
ARBLOST
R/W
Atmel AVR XMEGA AU
3
0
Operation
Reserved
Execute acknowledge action succeeded by
repeated START condition
No operation
Execute acknowledge action succeeded by
a byte receive
Execute acknowledge action succeeded by
issuing a STOP condition
BUSERR
R/W
2
0
R/W
1
0
BUSSTATE[1:0]
R/W
0
0
STATUS
274