AD5314 Analog Devices, AD5314 Datasheet - Page 19

no-image

AD5314

Manufacturer Part Number
AD5314
Description
Manufacturer
Analog Devices
Datasheet

Specifications of AD5314

Resolution (bits)
10bit
Dac Update Rate
143kSPS
Dac Settling Time
7µs
Max Pos Supply (v)
+5.5V
Single-supply
Yes
Dac Type
Voltage Out
Dac Input Format
Ser,SPI

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
AD5314ACPZ
Manufacturer:
ADI/亚德诺
Quantity:
20 000
Part Number:
AD5314ACPZ-REEL7
Manufacturer:
AD
Quantity:
359
Part Number:
AD5314ACPZ-REEL7
Manufacturer:
AD
Quantity:
8 000
Part Number:
AD5314ACPZ-REEL7
Manufacturer:
ADI/亚德诺
Quantity:
20 000
Part Number:
AD5314ARM
Manufacturer:
AD
Quantity:
5 510
Part Number:
AD5314ARM
Manufacturer:
ADI/亚德诺
Quantity:
20 000
Part Number:
AD5314ARM-REEL
Manufacturer:
AD
Quantity:
5 510
Part Number:
AD5314ARM-REEL
Manufacturer:
INFINEON
Quantity:
5 510
Part Number:
AD5314ARMZ
Manufacturer:
ADI/亚德诺
Quantity:
20 000
Part Number:
AD5314ARMZ-REEL7
Manufacturer:
ADI/亚德诺
Quantity:
20 000
Part Number:
AD5314BCPZ-REEL7
Manufacturer:
AD
Quantity:
290
Data Sheet
Opto-Isolated Interface for Process Control Applications
The AD5304/AD5314/AD5324 have a versatile 3-wire serial
inter-face, making them ideal for generating accurate voltages
in process control and industrial applications. Due to noise,
safety requirements, or distance, it might be necessary to isolate
the AD5304/AD5314/AD5324 from the controller. This can
easily be achieved by using opto-isolators, which provide isolation
in excess of 3 kV. The actual data rate achieved is limited by the
type of optocouplers chosen. The serial loading structure of the
AD5304/AD5314/AD5324 makes them ideally suited for use in
opto-isolated applications. Figure 42 shows an opto-isolated
interface to the AD5304 where DIN, SCLK, and SYNC are driven
from optocouplers. The power supply to the part also needs to
be isolated. This is done by using a transformer. On the DAC
side of the transformer, a 5 V regulator provides the 5 V supply
required for the AD5304.
DECODING MULTIPLE AD5304/AD5314/AD5324S
The SYNC pin on the AD5304/AD5314/AD5324 can be used
in applications to decode a number of DACs. In this application, all
the DACs in the system receive the same serial clock and serial
data, but SYNC can only be active to one of the devices at any one
time, allowing access to four channels in this 16-channel system.
The 74HC139 is used as a 2-to-4-line decoder to address any of the
DACs in the system. To prevent timing errors, the enable input
must be brought to its inactive state while the coded address
inputs are changing state. Figure 43 shows a diagram of a typical
setup for decoding multiple AD5304 devices in a system.
POWER
SYNC
SCLK
DIN
Figure 42. AD5304 in an Opto-Isolated Interface
10kΩ
10kΩ
10kΩ
REGULATOR
V
V
V
DD
DD
DD
5V
SCLK
SYNC
DIN
AD5304
V
GND
DD
V
V
V
V
REFIN
OUT
OUT
OUT
OUT
10µF
A
B
C
D
0.1µF
Rev. H | Page 19 of 24
AD5304/AD5314/AD5324 as a Digitally Programmable
Window Detector
A digitally programmable upper/lower limit detector using two
DACs in the AD5304/AD5314/AD5324 is shown in Figure 44.
The upper and lower limits for the test are loaded to DAC A
and DAC B, which, in turn, set the limits on the CMP04. If the
signal at the V
an LED indicates the fail condition. Similarly, DAC C and DAC D
can be used for window detection on a second V
V
*ADDITIONAL PINS OMITTED FOR CLARITY.
REF
SYNC
SCLK
5V
ADDRESS
DIN
ENABLE
CODED
SCLK
DIN
Figure 43. Decoding Multiple AD5304 Devices in a System
0.1µF
REFIN
AD5304/AD5314/
DIN
SCLK
SYNC
AD5324*
IN
1G
1A
1B
input is not within the programmed window,
10µF
1/2
GND
74HC139
DGND
Figure 44. Window Detection
V
V
V
V
V
DD
CC
DD
OUT
OUT
AD5304/AD5314/AD5324
A
B
1Y0
1Y1
1Y2
1Y3
V
IN
CMP04
1/2
SYNC
DIN
SCLK
SYNC
DIN
SCLK
SYNC
DIN
SCLK
SYNC
DIN
SCLK
AD5304
AD5304
AD5304
AD5304
PASS/FAIL
1/6 74HC05
1kΩ
FAIL
IN
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
signal.
OUT
OUT
OUT
OUT
OUT
OUT
OUT
OUT
OUT
OUT
OUT
OUT
OUT
OUT
OUT
OUT
A
B
C
D
A
B
C
D
A
B
C
D
A
B
C
D
1kΩ
PASS

Related parts for AD5314