7. COMMAND
Table 4 lists the commands. S1D12200 Series identifies
the data bus signal using different combinations of A0
and WR (E). High speed command interpretation and
execution are possible since only the internal timing is
used.
• Command Overview
Instruction execution duration of dependents on the
internal process time of S1D12200 Series, therefore it is
neces-sary to provide a duration larger than the system
cycle time (t
in-struction.
• Description of Commands
(1) Cursor Home
(2) Display ON/OFF Control
Note: Symbols driven by COMSA and SEGSA – E
Rev. 1.4
Display control
instruction
Power control
System set
Address control
instruction
Data input
instruction
Command type
alternately. The alternating display will be repeated
with approx. 1 second interval.
C registers and the cursor.
This command presets the address counter to 30H
and moves the cursor, when it is present, to the first
digit of the first line.
This command performs on or off of display and
cursor setting.
D
B
Blink displays characters in black and white,
C
Following table shows relationship between B and
A0 WR D7 D6 D5 D4 D3 D2 D1 D0
A0 WR D7 D6 D5 D4 D3 D2 D1 D0
0
0
must be controlled through the static icon
RAM.
0
0
CYC
= 0
= 0
= 0
) between execution of two successive
0
0
1
1
1
Cusor Home
Display ON/OFF Control
Power Save
Power Control
System set
Address Set
Data Write
0
0
: Display off
: Display on
: Cursor blink off
: Cursor blink on
: Display of cursor
: Does not display
Command name
0
1
1
1
*
C
B
*
: Don't Care
*
*
A0 WR
0
0
0
0
0
0
1
D
*
0
0
0
0
0
0
0
EPSON
(3) Power Save
(4) Supply Control
C
0
0
1
1
(C, B)
The cursor position indicates the position of address
counter.
Therefore, whenever moving the cursor, change
the address counter value using the RAM address
set command or the auto increment done by writing
the RAM data.
ISelective flashing symbol display is possible by
selecting (C, B) = (1, 0) and thus locating the
address counter to the position of the symbol register
through selecting (since the symbol is corresponding
to the character at each 5 dots).
This command is used to controlling the oscillation
circuit and setting or resetting the sleep mode.
PS
O
This command is used for controlling operation of
the built-in power circuit.
P
Note: The oscillation circuit must be turned on
A0 WR D7 D6 D5 D4 D3 D2 D1 D0
A0 WR D7 D6 D5 D4 D3 D2 D1 D0
0
0
B
0 Non-display
1 Non-display
0 Underbar cursor
1 Alternate display of display
(0, 0)
0
0
characters in black and white.
The cursor position indicates the
position of address
for the amplitying circuit to be active.
= 0
= 0
= 0
0
0
1
1
1
(1, 0)
1
1
: Power save off (reset)
: Power save on (set)
: Oscillating circuit off (stop of
: Oscillating circuit on (oscilla
: Amplifying circuit off
: Amplifying circuit on
Cursor display
oscillation)
tion)
0
0
0
1
S1D12200 Series
*
0 VC VF P
f Blink
(1, 1)
*
: Don't Care
O PS
2–21