LM3812M-1.0 National Semiconductor, LM3812M-1.0 Datasheet - Page 10

no-image

LM3812M-1.0

Manufacturer Part Number
LM3812M-1.0
Description
Precision Current Gauge IC with Ultra Low Loss Sense Element and PWM Output
Manufacturer
National Semiconductor
Datasheet
www.national.com
Product Operation
The current is sampled by the delta-sigma modulator, as il-
lustrated in Figure 6 . The pulse density output of the
delta-sigma modulator is digitally filtered. The digital output
is then compared to the output of a digital ramp generator.
This produces a PWM output. The duty cycle of the PWM
output is proportional to the amount of current flowing. A duty
cycle of 50% indicates zero current flow. If the current is flow-
ing in positive direction, the duty cycle will be greater than
50%. Conversely, the duty cycle will be less than 50% for
currents flowing in the negative direction. A duty cycle of
95.5% (4.5%) indicates the current is at I
can sense currents from −I
1A or 10A. The sense current is given by:
where D is the duty cycle of the PWM waveform, and I
the full scale current (1A or 10A). Similarly, the duty cycle is
given by:
For quick reference, see the Conversion Tables in Table 1
and Table 2 .
D = [I
I
SENSE
SENSE
= 2.2 (D−0.5)(I
MAX
/(2.2 I
to +I
FIGURE 6. Functional block diagram of LM3812 and LM3813
MAX
MAX
)] + 0.5
MAX
. Options for I
MAX
)
(−I
MAX
). The IC
MAX
MAX
are
is
10
The user should note that, while the LM3812-7.0/
LM3813-7.0 will read 10A full scale, it is rated for 10A op-
eration for a duration of no more than 200 msec, and 7A
operation continuously.
In this IC, the current is averaged over 50 msec time slots.
Hence, momentary current surges of less than 50 msec are
tolerated.
This is a sampled data system which requires an
anti-aliasing filter, provided by the filter capacitor.
The delta-sigma modulator converts the sensed current to
the digital domain. This allows digital filtering, and provides
immunity to current and noise spikes. This type of filtering
would be difficult or impossible to accomplish on an IC with
analog components.
When ordering, the user has to specify whether the part is
being used for low-side or high-side sense. The user also
needs to specify the full scale value. See the Ordering Infor-
mation table for details.
DS100122-10

Related parts for LM3812M-1.0