MAX6900 Maxim, MAX6900 Datasheet - Page 5

no-image

MAX6900

Manufacturer Part Number
MAX6900
Description
I2C-Compatible RTC in a TDFN
Manufacturer
Maxim
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
MAX6900ETT
Manufacturer:
MAXIM/美信
Quantity:
20 000
Part Number:
MAX6900ETT+
Manufacturer:
Maxim
Quantity:
600
Part Number:
MAX6900ETT+
Manufacturer:
MAXIM
Quantity:
90
Part Number:
MAX6900ETT+T
Manufacturer:
MAXIM
Quantity:
1 587
Company:
Part Number:
MAX6900ETT+T
Quantity:
42 761
Part Number:
MAX6900TT
Manufacturer:
FAIRCHILD
Quantity:
300
Figure 2. Functional Diagram
days, including corrections for leap year up to the year
2100.
The MAX6900 uses an external, standard 12.5pF load
watch crystal. No other external components are
required for this timekeeping oscillator. Power-up oscil-
lator start-time is dependent mainly upon applied V
and ambient temperature. The MAX6900, because of
its low timekeeping current, exhibits a typical startup
time between 5s to 10s.
Interfacing the MAX6900 with a microprocessor or
other I
bus-compatible or other I
wires are required to communicate with the clock and
SRAM: SCL (serial clock) and SDA (data line). Data is
transferred to and from the MAX6900 over the I/O data
line, SDA. The MAX6900 uses 7-bit slave ID address-
ing. The MAX6900 does not respond to general call
address commands.
2
C master is made easier by using the serial, I
_______________________________________________________________________________________
I
2
C-Compatible Interface
2
C master interface. Only 2
GND
VCC
SDA
SCL
X1
X2
Crystal Oscillator
OSCILLATOR
INTERFACE
32.768kHz
I
2
C BUS
I
2
C-Compatible RTC in a TDFN
CONTROL
2
LOGIC
CC
DIVIDER
C-
ADDRESS
REGISTER
The I
tional, 2-wire communication between multiple ICs. The
two lines are SDA and SCL. Connect both lines to a
positive supply through individual pullup resistors. A
device on the I
message is called a transmitter and a device that
receives the message is a receiver. The device that
controls the message is the master and the devices
that are controlled by the master are called slaves
(Figure 3). The word message refers to data in the form
of three 8-bit bytes for a Single Read or Write. The first
byte is the Slave ID byte, the second byte is the
Address/Command byte, and the third is the data.
Data transfer can only be initiated when the bus is not
busy (both SDA and SCL are high). A high-to-low tran-
sition of SDA while SCL is high is defined as the Start
(S) condition; low-to-high transition of the data line
while SCL is high is defined as the Stop (P) condition
(Figure 4).
31 X 8
SRAM
1Hz
2
C-bus-compatible serial interface allows bidirec-
SECONDS
CONTROL
CENTURY
Applications Information
MINUTES
MONTH
HOURS
CLOCK
BURST
DATE
YEAR
2
DAY
C-compatible bus that generates a
I
2
C-Bus-Compatible Interface
5

Related parts for MAX6900