HY27UF081G2M Hynix Semiconductor, HY27UF081G2M Datasheet - Page 41

no-image

HY27UF081G2M

Manufacturer Part Number
HY27UF081G2M
Description
(HY27UF(08/16)1G2M / HY27SF(08/16)1G2M) 1Gbit (128Mx8bit/64Mx16bit) NAND Flash Memory
Manufacturer
Hynix Semiconductor
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
HY27UF081G2M
Manufacturer:
HY
Quantity:
1 000
Part Number:
HY27UF081G2M
Manufacturer:
HY
Quantity:
1 000
Part Number:
HY27UF081G2M
Manufacturer:
HY
Quantity:
5 530
Part Number:
HY27UF081G2M-TCB
Manufacturer:
HYNIX
Quantity:
16
Part Number:
HY27UF081G2M-TPCB
Manufacturer:
HYNIX/海力士
Quantity:
20 000
Company:
Part Number:
HY27UF081G2M-TPCB
Quantity:
848
Preliminary
HY27UF(08/16)1G2M Series
HY27SF(08/16)1G2M Series
1Gbit (128Mx8bit / 64Mx16bit) NAND Flash
Bad Block Management
Devices with Bad Blocks have the same quality level and the same AC and DC characteristics as devices where all the
blocks are valid. A Bad Block does not affect the performance of valid blocks because it is isolated from the bit line and
common source line by a select transistor. The devices are supplied with all the locations inside valid blocks
erased(FFh). The Bad Block Information is written prior to shipping. Any block where the 1st Byte in the spare area of
the 1st or 2nd page(if the 1st page is Bad) does not contain FFh is a Bad Block. The Bad Block Information must be
read before any erase is attempted as the Bad Block Information may be erased. For the system to be able to recog-
nize the Bad Blocks based on the original information it is recommended to create a Bad Block table following the flow-
chart shown in Figure 29.
Block Replacement
Over the lifetime of the device additional Bad Blocks may develop. In this case the block has to be replaced by copying
the data to a valid block. These additional Bad Blocks can be identified as attempts to program or erase them will give
errors in the Status Register.
As the failure of a page program operation does not affect the data in other pages in the same block, the block can be
replaced by re-programming the current data and copying the rest of the replaced block to an available valid block.
The Copy Back Program command can be used to copy the data to a valid block.
See the “Copy Back Program” section for more details.
Refer to Table 18 for the recommended procedure to follow if an error occurs during an operation.
Operation
Recommended Procedure
Erase
Block Replacement
Program
Block Replacement or ECC
Read
ECC
Table 18: Block Failure
Figure 29: Bad Block Management Flowchart
Rev 0.6 / Mar. 2005
41