Specifications
Note: 1. Inductive loads have a power factor of 0.4 min. (AC) and a time constant of 7 ms max. (DC).
Microvoltage/Current Load Model (WL01 )
Rated
voltage
125 VAC
250 VAC
480 VAC
600 VAC
8 VDC
14 VDC
30 VDC
125 VDC
250 VDC
Rated voltage
125 VAC
30 VDC
GENERAL RATINGS
2. Lamp load has an inrush current of 10 times the steady-state current.
3. Motor load has an inrush current of 6 times the steady-state current.
Operating Head
Roller lever, rod lever and side
plunger types may be locked in
at any of four 90 positions.
Proper Operation Zone Markers
Two raised markers on the shaft
housing indicate the proper limits
for normal operation to simplify
installation.
Non-inductive load
Resistive load
NC
10 A
10 A
10 A
3 A
10 A
10 A
6 A
0.8 A
0.4 A
Too much Overtravel, adjustment needed.
Normal operation
Too little Overtravel, adjustment needed.
Normal operation
Too much Overtravel, adjustment needed.
Axis Bearing
Assures smooth plunger movement.
Resistive Load
0.1 A
NO
10 A
10 A
10 A
1 A
Shaft Seal
O-ring provides a high
degree of sealing.
Built-in Switch
Long mechanical life of 15
million operations, minimum.
Lamp load
NC
3 A
2 A
1.5 A
1 A
6 A
6 A
4 A
0.2 A
0.1 A
NO
1.5A
1 A
0.8 A
0.5 A
3 A
3 A
3 A
7
Conduit Entrance
1/2-14 NPT
Inductive load
Inductive load
NC
10 A
10 A
3 A
1.5 A
10 A
10 A
6 A
0.8 A
0.4 A
NO
Roller
Sintered stainless steel with self-
lubricating bearing resists wear.
Lever
Aluminum alloy resists corrosion.
Roller Lever Mounting Screw
Cover Seal
O-ring provides a high
degree of sealing.
Terminal Screws
Four M4 screws
Insulation
Material provides insulation and
seals out corrosive gas.
Cover Mounting Screws
Self-retaining Phillips head
screws will not fall out.
Motor load
NC
5 A
3 A
1.5 A
1 A
6 A
6 A
4 A
0.2 A
0.1 A
NO
2.5 A
1.5 A
0.8 A
0.5 A
WL