ds7505 Maxim Integrated Products, Inc., ds7505 Datasheet - Page 7

no-image

ds7505

Manufacturer Part Number
ds7505
Description
High-precision Digital Thermometer And Thermostat
Manufacturer
Maxim Integrated Products, Inc.
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
DS7505
Manufacturer:
DALLAS
Quantity:
20 000
Part Number:
ds7505U
Manufacturer:
MAXIM/美信
Quantity:
20 000
Company:
Part Number:
ds7505U+
Quantity:
300
Figure 4. O.S. Output Operation Example
In interrupt mode, the O.S. output first becomes active
when the measured temperature exceeds the T
value a consecutive number of times equal to the FT
value in the configuration register. Once activated, O.S.
can only be cleared by either putting the DS7505 into
shutdown mode or by reading from any register (tem-
perature, configuration, T
Once O.S. has been deactivated, it is only reactivated
IN THIS EXAMPLE, THE DS7505 IS CONFIGURED
TO HAVE A FAULT TOLERANCE OF 2.
O.S. OUTPUT—COMPARATOR MODE
_______________________________________________________________________________________
O.S. OUTPUT—INTERRUPT MODE
Digital Thermometer and Thermostat
OS
, or T
TEMPERATURE
HYST
Interrupt Mode
) on the device.
INACTIVE
INACTIVE
ACTIVE
ACTIVE
T
HYST
T
OS
OS
when the measured temperature falls below the T
value a consecutive number of times equal to the FT
value. Again, O.S can only be cleared by putting the
device into shutdown mode or reading any register.
Thus, this interrupt/clear process is cyclical between
T
T
mode operation with FT = 2 is illustrated in Figure 4.
OS
OS
, clear, T
and T
CONVERSIONS
HYST
HYST
events (i.e, T
ASSUMES A READ
, clear, etc.). Thermostat interrupt
HAS OCCURED
OS
, clear, T
HYST
, clear,
HYST