t18xsd1eq Banner Engineering Corp., t18xsd1eq Datasheet - Page 8

no-image

t18xsd1eq

Manufacturer Part Number
t18xsd1eq
Description
Manufacturer
Banner Engineering Corp.
Datasheet
page
Attribute
8
11
12
13
14
15
18
51
56
58
60
61
T18XSD Series
Serial Number
Date Code
Catalog listing
Vendor Name
Device Name
Input Variable
Direct Input State:
Tag Name
Diagnostic Count Limit
NO/NC
Configuration Register
Description
This is a single byte, 8 flags.
This is a single byte, 8 flags.
This attribute is stored in non-volatile memory.
Unique number used to differentiate products prior to address assignment. The firmware waits
for a random period of up to 10 ms before responding to a read of this attribute. This makes it
possible to detect two nodes with the same address.
ASCII string that identifies date of manufacture.
ASCII string = “T18XSD1XXX” (Model number)
ASCII String = “Banner Engineering”
ASCII String = “Photoelectric Sensor”
This reflects the state of the sensor output: 0 = Dark, 1 = Light. The logical state of this
attribute can be inverted by setting attribute 61, NO/NC. The state of this attribute may also be
forced by using action 51, Force State.
This is a read/write 24 character ASCII string. This attribute is stored in non-volatile memory.
Each time a low gain condition occurs, it is counted. When that count reaches the diagnostic
count limit, the diagnostic register is updated and an event 0 is sent. Here are some possible
values for the diagnostic count limit:
Setting this bit will invert the Input State (attribute 18). This attribute is stored in
non-volatile memory
Possible values of Attribute 51 are:
bit 0
bit 1
bits 2 to 7 = 0, not used.
51 = 0 Dark
51 = 1 Low Gain
51 = 3 Light; The NO/NC bit (attribute #60) does not affect this register.
bits 0 to 2 Not used.
bit 3
bits 4 to 7 Not used.
0
1
20 = Low gain bit is set after 20 low gain conditions
= Low gain alarm disabled
= Low gain bit set each time low gain condition occurs
Real time sense level, high when excess gain > 1
Real time diagnostics signal, high when excess gain > 2.5
(Sensor sees Light, and Alarm is off)
Disable re-transmission of COS messages R/W. When this bit is set ALL event driven
messages are sent only once per event. Unacknowledged messages are not resent.
Attributes
Banner Engineering Corp. • Minneapolis, U.S.A.
Website: http://www.baneng.com • Tel: 888.373.6767
Action