ltc1760 Linear Technology Corporation, ltc1760 Datasheet - Page 20

no-image

ltc1760

Manufacturer Part Number
ltc1760
Description
Dual Smart Battery System Manager
Manufacturer
Linear Technology Corporation
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ltc1760CFW
Manufacturer:
Linear Technology
Quantity:
1 855
Part Number:
ltc1760CFW
Manufacturer:
ST
Quantity:
215
Part Number:
ltc1760CFW
Manufacturer:
LT
Quantity:
1 000
Part Number:
ltc1760CFW
Manufacturer:
LT/凌特
Quantity:
20 000
Part Number:
ltc1760CFW#PBF
Manufacturer:
LT
Quantity:
2
Part Number:
ltc1760CFW#PBF
Manufacturer:
LINEAR/凌特
Quantity:
20 000
Part Number:
ltc1760IFW#PBF
Manufacturer:
LT
Quantity:
2 000
Part Number:
ltc1760IFW#PBF
Manufacturer:
LINEAR/凌特
Quantity:
20 000
Part Number:
ltc1760IFW#TRPBF
Manufacturer:
LINEAR/凌特
Quantity:
20 000
LTC1760
OPERATIO
20
2.3.7 Current() ('h0a)
Description:
This function is used by the LTC1760 to read the actual
current being supplied through the battery terminals.
Purpose:
Allows the LTC1760 to determine how much current a
battery is receiving through its terminals and close the
charging current servo loop.
SMBus Protocol: Read Word. LTC1760 reads Battery 1 or
Battery 2 as an SMBus Master.
Output: signed integer (2’s complement) — charge/dis-
charge rate in mA increments - positive for charge, nega-
tive for discharge. Refer to "Section 2.2" for bit mapping.
Units: mA.
Range: 0 to 32,767 mA for charge or 0 to -32,768 mA for
discharge.
2.3.8 ChargingCurrent() ('h14)
Description:
This function is used by the LTC1760 to read the Smart
Battery’s desired charging current.
Purpose:
Allows the LTC1760 to determine the maximum charging
current.
SMBus Protocol: Read Word. LTC1760 reads Battery 1 or
Battery 2 as an SMBus Master.
Output: unsigned integer — maximum charger output
current in mA. Refer to "Section 2.2" for bit mapping.
Units: mA.
Range: 0 to 65,534 mA.
2.3.9 ChargingVoltage() ('h15)
Description:
This function is used by the LTC1760 to read the Smart
Battery’s desired charging voltage.
U
Purpose:
Allows the LTC1760 to determine the maximum charging
voltage.
SMBus Protocol: Read Word. LTC1760 reads Battery 1 or
Battery 2 as an SMBus Master.
Output: unsigned integer — charger output voltage in mV.
Refer to Section 2.2 for bit mapping.
Units: mV.
Range: 0 to 65,534 mV.
2.3.10 AlarmWarning () ('h16)
Description:
This function is used by the LTC1760 to read the Smart
Battery alarm register.
Purpose:
Allows the LTC1760 to determine the state of all applicable
alarm flags.
SMBus Protocol: Read Word. LTC1760 reads Battery 1 or
Battery 2 as an SMBus Master.
Output: unsigned integer – Refer to “Section 2.2” for bit
mapping.
OVER_CHARGED_ALARM Bit
The read only OVER_CHARGED_ALARM bit is used by the
LTC1760 to determine if charging may continue.
Allowed values are:
TERMINATE_CHARGE_ALARM Bit
The read only TERMINATE_CHARGE_ALARM bit is used
by the LTC1760 to determine if charging may continue.
Allowed values are:
'b1: The LTC1760 will not charge this battery.
'b0: The LTC1760 may charge this battery if other
conditions permit charging.
'b1: The LTC1760 will not charge this battery.
'b0: The LTC1760 may charge this battery if other
conditions permit charging.
1760f

Related parts for ltc1760