sy89465u Micrel Semiconductor, sy89465u Datasheet - Page 12

no-image

sy89465u

Manufacturer Part Number
sy89465u
Description
Sy89465u Precision Lvds 1 10 Fanout With 2 1 Runt Pulse Eliminator Mux And Internal Termination
Manufacturer
Micrel Semiconductor
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
sy89465uMG TR
Manufacturer:
MICREL
Quantity:
2 960
Part Number:
sy89465uMY
Manufacturer:
Semtech
Quantity:
984
Enable Output (EN) Description
The enable function is synchronous so that the
outputs will be enabled/disabled when they are
already in the LOW state. This avoids any chance of
generating a runt pulse when the device is
enabled/disabled as can happen with asynchronous
control.
Disable Output(s):
December 2007
1. EN toggles from High-to-Low
2. Output(s) follow the selected Clock input
3. Output (CLK) goes to a logic LOW level
(/CLK goes to a logic HIGH), after next High-
to-Low transition of the selected input. See
Timing Diagram 5.
Timing Diagram 5
12
Enable Output(s):
1. EN toggles from Low-to-High.
2. Output(s) follow the selected clock after next
HIGH-to-LOW transition of the selected
input. See “Timing Diagram 5.”
hbwhelp@micrel.com
M9999-120607-B
or (408) 955-1690